6 Commissioning Issue 10/06<br />

6.4.18.10 Positioning down ramp<br />

P0500 = ...<br />

P2481 = ...<br />

P2482 = ...<br />

P2484 = ...<br />

P2488 = ...<br />

Technological application<br />

0<br />

f<br />

1<br />

s = P2488 = ⋅ f .<br />

OFF1<br />

t<br />

2<br />

P2488<br />

OFF1<br />

f OFF1<br />

Selects technological application. Sets control mode (P1300).<br />

0 Constant torque<br />

1 Pumps and fans<br />

3 Simple Positioning<br />

Gearbox ratio input<br />

1.00<br />

Defines the ratio between number of motor shaft revolutions to equal one revolution of the<br />

gearbox output shaft.<br />

Motor<br />

Gear<br />

Load<br />

Ü<br />

n<br />

Motor<br />

n<br />

Load<br />

Ü =<br />

Motor revolutions P2481<br />

=<br />

Load revolutions P2482<br />

Gearbox ratio output<br />

1.00<br />

Defines the ratio between number of motor shaft revolutions to equal one revolution of the<br />

gearbox output shaft.<br />

No. of shaft turns = 1 Unit<br />

1.00<br />

Sets the number of rotations of the motor shaft required to represent 1 unit of user<br />

selected units.<br />

Pulley radius r<br />

Distance s<br />

Load<br />

U<br />

U<br />

P2484 = = s<br />

No. of revolutions<br />

1 [unit]<br />

Distance / No. of revolutions<br />

1.00<br />

Sets the required distance or number of revolutions (see P2484).<br />