6 Commissioning Issue 10/06<br />

Drive data set (DDS)<br />

Drive data set (DDS) bit 0<br />

0<br />

P0820 = ...<br />

Selects the command source from which bit 0 should be read-out to select a drive data set.<br />

Operation<br />

Ready<br />

Select DDS<br />

t<br />

BI: DDS bit 1<br />

P0821<br />

(0:0)<br />

3<br />

2<br />

CO/BO: Act CtrlWd2<br />

r0055 .05<br />

r0055 .05<br />

BI: DDS bit 0<br />

P0820<br />

(0:0)<br />

Active DDS<br />

r0051[1]<br />

1<br />

0<br />

3<br />

Changeover time<br />

approx. 50 ms<br />

CO/BO: Act CtrlWd2<br />

r0055 .04<br />

r0055 .04<br />

t<br />

Changeover time<br />

approx. 50 ms<br />

2<br />

1<br />

CO: Active DDS<br />

r0051 .01 [2]<br />

P0821 = ...<br />

0<br />

The currently active drive data set (DDS) is displayed using parameter r0051[1].<br />

BI: DDS bit 1<br />

0:0<br />

Selects command source from which Bit 1 for selecting a drive data set is to be read in<br />

(see parameter P0820).<br />

t<br />

<strong>MICROM<strong>AS</strong>TER</strong> <strong>440</strong><br />

70 Operating Instructions (Compact)