6 Commissioning Issue 10/06<br />
6.4.10 JOG<br />
P1058 = ...<br />
JOG frequency right<br />
5.00 Hz<br />
Frequency in Hz when the motor is<br />
rotating clockwise in the jog mode.<br />
JOG<br />
P1059 = ...<br />
P1060 = ...<br />
JOG frequency left<br />
5.00 Hz<br />
Frequency in Hz when the motor is<br />
rotating counter-clockwise in the jog<br />
mode.<br />
JOG ramp-up time<br />
10.00 s<br />
Ramp-up time in s from 0 to the<br />
maximum frequency (p1082). JOG rampup<br />
is limited by p1058 or p1059.<br />
p1082<br />
(f max<br />
)<br />
p1058<br />
f<br />
P1061 = ...<br />
JOG ramp-down time<br />
10.00 s<br />
Ramp-down time in s from the maximum<br />
frequency (p1082) to 0.<br />
p1060<br />
p1061<br />
t<br />
A0923<br />
A0923<br />
DIN<br />
BOP<br />
Tippen rechts<br />
P1055<br />
(0)<br />
"1"<br />
"0"<br />
t<br />
USS<br />
BOP link<br />
USS<br />
COM link<br />
CB<br />
COM link<br />
"1"<br />
Tippen links<br />
P1056 "0"<br />
(0)<br />
P1082<br />
P1058<br />
f<br />
t<br />
t<br />
P1059<br />
-P1082<br />
P1060<br />
P1061<br />
P1060<br />
P1061<br />
<strong>MICROM<strong>AS</strong>TER</strong> <strong>440</strong><br />
42 Operating Instructions (Compact)