Issue 10/06<br />

1 Installation<br />

1 Installation<br />

1.1 Clearance distances for mounting<br />

The inverters can be mounted adjacent to each other. When mounting inverters<br />

one above the other, the specified environmental conditions must not be exceeded.<br />

Independent of this, these minimum distances must be observed.<br />

‣ Frame Size A, B, C<br />

‣ Frame Size D, E<br />

‣ Frame Size F<br />

‣ Frame Size FX, GX<br />

above and below 100 mm<br />

above and below 300 mm<br />

above and below 350 mm<br />

above 250 mm<br />

below 150 mm<br />

in front 40 mm (FX), 50 mm (GX)<br />

1.2 Mounting dimensions<br />

Frame<br />

Size<br />

Drilling Dimensions<br />

Tightening Torque<br />

H<br />

mm (Inch)<br />

W<br />

mm (Inch)<br />

Bolts<br />

Nm<br />

(lbf.in)<br />

H<br />

A 160 (6.30) – 2 x M4<br />

B 174 (6.85) 138 (5.43) 4 x M4<br />

C 204 (8.03) 174 (6.85) 4 x M5<br />

D 486 (19.13) 235 (9.25) 4 x M8<br />

2,5<br />

(22.12)<br />

W<br />

E 616,4<br />

(24.27)<br />

235 (9.25) 4 x M8<br />

F 810 (31.89) 300 (11.81) 4 x M8<br />

3,0<br />

(26.54)<br />

FX 1375,5<br />

(54.14)<br />

GX 1508,5<br />

(59.38)<br />

250 (9.84) 6 x M8 13,0<br />

(115.02)<br />

250 (9.84) 6 x M8 13,0<br />

(115.02)<br />

Fig. 1-1<br />

Mounting dimensions<br />

<strong>MICROM<strong>AS</strong>TER</strong> <strong>440</strong><br />

Operating Instructions (Compact) 5