Issue 10/06<br />
1 Installation<br />
1 Installation<br />
1.1 Clearance distances for mounting<br />
The inverters can be mounted adjacent to each other. When mounting inverters<br />
one above the other, the specified environmental conditions must not be exceeded.<br />
Independent of this, these minimum distances must be observed.<br />
‣ Frame Size A, B, C<br />
‣ Frame Size D, E<br />
‣ Frame Size F<br />
‣ Frame Size FX, GX<br />
above and below 100 mm<br />
above and below 300 mm<br />
above and below 350 mm<br />
above 250 mm<br />
below 150 mm<br />
in front 40 mm (FX), 50 mm (GX)<br />
1.2 Mounting dimensions<br />
Frame<br />
Size<br />
Drilling Dimensions<br />
Tightening Torque<br />
H<br />
mm (Inch)<br />
W<br />
mm (Inch)<br />
Bolts<br />
Nm<br />
(lbf.in)<br />
H<br />
A 160 (6.30) – 2 x M4<br />
B 174 (6.85) 138 (5.43) 4 x M4<br />
C 204 (8.03) 174 (6.85) 4 x M5<br />
D 486 (19.13) 235 (9.25) 4 x M8<br />
2,5<br />
(22.12)<br />
W<br />
E 616,4<br />
(24.27)<br />
235 (9.25) 4 x M8<br />
F 810 (31.89) 300 (11.81) 4 x M8<br />
3,0<br />
(26.54)<br />
FX 1375,5<br />
(54.14)<br />
GX 1508,5<br />
(59.38)<br />
250 (9.84) 6 x M8 13,0<br />
(115.02)<br />
250 (9.84) 6 x M8 13,0<br />
(115.02)<br />
Fig. 1-1<br />
Mounting dimensions<br />
<strong>MICROM<strong>AS</strong>TER</strong> <strong>440</strong><br />
Operating Instructions (Compact) 5