6 Commissioning Issue 10/06<br />
r1079<br />
CO: Selected frequency setpoint<br />
Displays the selected frequency setpoint.<br />
The following frequency setpoints are displayed:<br />
• r1078 total setpoint (HSW + ZUSW)<br />
• P1058 JOG frequency, clockwise<br />
• P1059 JOG frequency, counter-clockwise.<br />
JOG<br />
P1110 P1091 P1080 P1082 P1120 P1135<br />
. . .<br />
Setpoint<br />
source<br />
Reverse<br />
Inhibit<br />
neg. freq.<br />
setpoint<br />
Skip<br />
frequency<br />
IfI<br />
RFG<br />
Motor<br />
control<br />
r1079 r1114<br />
r0020 r1170<br />
r1078<br />
r1119<br />
r1114<br />
r1170<br />
CO: Freq. setpoint after dir. ctrl.<br />
Displays the setpoint (reference) frequency in Hz after the function block to reverse the<br />
direction of rotation.<br />
CO: : Frequency setpoint after RFG<br />
Displays the total frequency setpoint (reference value) in Hz after the ramp-function<br />
generator.<br />
<strong>MICROM<strong>AS</strong>TER</strong> <strong>440</strong><br />