Advanced Operation<br />

RS-232 / IP Commands<br />

#set_http_port<br />

The #set_http_port command specifies the Web server listening port. The matrix must<br />

be rebooted after executing this command. The default port setting is 80. The current<br />

HTTP listening port can be displayed using the #show_http_port command.<br />

Syntax:<br />

#set_http_port param1<br />

Parameters:<br />

param1 Port [1 ... 1024]<br />

Example:<br />

#set_http_port 82<br />

HTTP Communication Port 82 Is Set. Please Reboot The Unit.<br />

#set_telnet_pass<br />

The #set_telnet_pass command sets the Telnet password. The password cannot<br />

exceed 20 characters in length. The matrix must be rebooted after executing this<br />

command. The default password is Admin.<br />

Syntax:<br />

#set_telnet_pass param1<br />

Parameters:<br />

param1<br />

Password<br />

Example:<br />

#set_telnet_pass reindeer<br />

TELNET Interface Password Is Set.<br />

page | 33