Advanced Operation<br />

RS-232 / IP Commands<br />

#set_webui_op_pass<br />

The #set_webui_ad_pass command sets the Operator password for the Web interface.<br />

The password cannot exceed 8 characters in length. The default password is Admin.<br />

To set the Administrator password, use the #set_webui_ad_pass command.<br />

Syntax:<br />

#set_webui_op_pass param1<br />

Parameters:<br />

param1<br />

Password<br />

Example:<br />

#set_webui_op_pass everest<br />

Web UI Administrator Password Is Set<br />

#sgateway<br />

The #sgateway command sets the new IP gateway. The gateway must be typed<br />

using dot-decimal notation. The matrix must be rebooted after executing this command.<br />

The default gateway is 192.168.1.254. Also see the #show_gateway and #ipconfig<br />

commands.<br />

Syntax:<br />

#sgateway param1<br />

Parameters:<br />

param1<br />

Gateway<br />

Example:<br />

#sgateway 192.168.1.1<br />

GateWay Address 192.168.1.1 Is Set. Please Reboot The Unit.<br />