Manual - Gefen
Manual - Gefen
Manual - Gefen
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Advanced Operation<br />
RS-232 / IP Commands<br />
#set_webui_op_pass<br />
The #set_webui_ad_pass command sets the Operator password for the Web interface.<br />
The password cannot exceed 8 characters in length. The default password is Admin.<br />
To set the Administrator password, use the #set_webui_ad_pass command.<br />
Syntax:<br />
#set_webui_op_pass param1<br />
Parameters:<br />
param1<br />
Password<br />
Example:<br />
#set_webui_op_pass everest<br />
Web UI Administrator Password Is Set<br />
#sgateway<br />
The #sgateway command sets the new IP gateway. The gateway must be typed<br />
using dot-decimal notation. The matrix must be rebooted after executing this command.<br />
The default gateway is 192.168.1.254. Also see the #show_gateway and #ipconfig<br />
commands.<br />
Syntax:<br />
#sgateway param1<br />
Parameters:<br />
param1<br />
Gateway<br />
Example:<br />
#sgateway 192.168.1.1<br />
GateWay Address 192.168.1.1 Is Set. Please Reboot The Unit.<br />
page | 35