Advanced Operation<br />
RS-232 / IP Commands<br />
#set_edid<br />
The #seet_edid command sets the specified EDID type for an input or EDID bank.<br />
Syntax:<br />
#set_edid param1 param2 param3 param4<br />
Parameters:<br />
param1 Source type [String]<br />
Src. type<br />
default<br />
dynamic<br />
bank<br />
output<br />
Description<br />
Uses default EDID<br />
Uses dynamic EDID<br />
Uses EDID bank<br />
used EDID on output (sink)<br />
param2 Source number [0 ... 8]<br />
Source no. Description<br />
0 Default EDID<br />
1 ... 8 EDID bank<br />
1 ... 8 Output<br />
param3 Target type [String]<br />
Target<br />
input<br />
bank<br />
Description<br />
Specifies an input<br />
Specifies an EDID bank<br />
param4 Target number [String]<br />
Target no. Description<br />
1 ... 8 Input<br />
1 ... 8 EDID bank<br />