Advanced Operation<br />

RS-232 / IP Commands<br />

#set_edid<br />

The #seet_edid command sets the specified EDID type for an input or EDID bank.<br />

Syntax:<br />

#set_edid param1 param2 param3 param4<br />

Parameters:<br />

param1 Source type [String]<br />

Src. type<br />

default<br />

dynamic<br />

bank<br />

output<br />

Description<br />

Uses default EDID<br />

Uses dynamic EDID<br />

Uses EDID bank<br />

used EDID on output (sink)<br />

param2 Source number [0 ... 8]<br />

Source no. Description<br />

0 Default EDID<br />

1 ... 8 EDID bank<br />

1 ... 8 Output<br />

param3 Target type [String]<br />

Target<br />

input<br />

bank<br />

Description<br />

Specifies an input<br />

Specifies an EDID bank<br />

param4 Target number [String]<br />

Target no. Description<br />

1 ... 8 Input<br />

1 ... 8 EDID bank<br />