Blades (<strong>FortiGate</strong>-5000 chassis slots)<br />

System Chassis (<strong>FortiGate</strong>-5000 series)<br />

Blades (<strong>FortiGate</strong>-5000 chassis slots)<br />

Go to System > Chassis > Blades to display a list of the slots in the<br />

<strong>FortiGate</strong>-5000 chassis that the <strong>FortiGate</strong>-5000 series module is installed in. The<br />

list of slots shows whether the slot is empty or contains a <strong>FortiGate</strong>-5000 module.<br />

If a slot contains a module, the display shows the type of module in the slot. Slots<br />

can contain node cards such as the <strong>FortiGate</strong>-5001SX module and switch cards<br />

such as the FortiSwitch-5003 module. The slot containing the <strong>FortiGate</strong>-5000<br />

module that you are connecting to is highlighted in yellow.<br />

If the <strong>FortiGate</strong>-5000 series module that you are connecting to is installed in a<br />

<strong>FortiGate</strong>-5050 chassis, the blades list contains 5 rows. For a <strong>FortiGate</strong>-5140<br />

chassis the blades list contains 14 rows.<br />

For each slot that contains a module, the blades list indicates if the monitored<br />

temperatures and voltages for the module in that slot are within acceptable<br />

ranges. If temperature and voltage show good, the module is operating with<br />

acceptable ranges. If temperature or voltage show alarm, the shelf manager has<br />

registered an alarm because a temperature or voltage is outside of the acceptable<br />

range.<br />

If you have SNMP enabled and have selected the Temperature too high and<br />

Voltage out of range SNMP events, when the shelf manager registers a<br />

temperature or voltage alarm, the <strong>FortiGate</strong>-5000 module SNMP agent sends an<br />

SNMP trap.<br />

Figure 116:Example <strong>FortiGate</strong>-5050 blades list<br />

Refresh interval<br />

Refresh<br />

Slot #<br />

Blade Type<br />

Set how often the web-based manager refreshes the information<br />

displayed on the blades list.<br />

Manually refresh the information displayed on the blades list.<br />

The slot number in the chassis. Slots 1 to 5 are listed for the<br />

<strong>FortiGate</strong>-5050 chassis and slots 1 to 14 are listed for the<br />

<strong>FortiGate</strong>-5140 chassis.<br />

Indicates whether the slot contains a node card (for example, a<br />

<strong>FortiGate</strong>-5001SX module) or a switch card (for example, a<br />

FortiSwitch-5003 module).<br />

<strong>FortiGate</strong> Version 3.0 MR5 <strong>Administration</strong> <strong>Guide</strong><br />