System Chassis (<strong>FortiGate</strong>-5000 series)<br />

Chassis monitoring event log messages<br />

Table 31: Chassis monitoring warning and critical event log messages<br />

ID Message Meaning<br />

99503 Chassis fan anomaly:<br />

Fan ,<br />

RPM<br />

Chassis fan anomaly<br />

99504 Chassis temperature<br />

anomaly: T<br />

,<br />

Celsius<br />

99505 Chassis voltage<br />

anomaly:<br />

V,<br />

V<br />

99506 Blade fan anomaly: Fan<br />

,<br />

RPM<br />

99507 Blade temperature<br />

anomaly: Blade<br />

,<br />

Celsius<br />

99508 Blade voltage anomaly:<br />

Blade<br />

,<br />

V<br />

A chassis fan is operating at an RPM value<br />

outside of the normal operating range.<br />

is the number of the fan tray. For<br />

the <strong>FortiGate</strong>-5140 can be 0, 1, or<br />

2. The <strong>FortiGate</strong>-5050 only has one fan tray.<br />

is the RPM at which the fan is<br />

operating.<br />

A temperature sensor has reported a<br />

temperature outside of the normal operating<br />

range for this sensor. A typical operating range is<br />

between 10 and 75 degrees Celsius.<br />

identifies the temperature<br />

sensor. is the temperature being<br />

reported by the sensor.<br />

A chassis voltage sensor has detected a voltage<br />

level outside of the operating range for the<br />

sensor. is the voltage the<br />

circuit should have at the sensor location during<br />

normal operation. For example,<br />

could be 3.3, 5, and so on.<br />

is the actual voltage<br />

measure by the sensor.<br />

A blade fan is operating at an RPM value outside<br />

of the normal operating range. <br />

identifies the fan. is the RPM at<br />

which the fan is operating.<br />

A temperature sensor on a <strong>FortiGate</strong>-5000 or<br />

FortiSwitch-5000 series module has reported a<br />

temperature outside of the normal operating<br />

range for this sensor. A typical operating range is<br />

between 10 and 75 degrees Celsius.<br />

identifies the module<br />

temperature sensor. is the<br />

temperature being reported by the sensor.<br />

A voltage sensor on a <strong>FortiGate</strong>-5000 or<br />

FortiSwitch-5000 series module has detected a<br />

voltage level outside of the operating range for<br />

the sensor. is the voltage the<br />

circuit should have at the sensor location during<br />

normal operation. For example,<br />

could be 3.3, 5, and so on.<br />

is the actual voltage<br />

measure by the sensor.<br />