System Chassis (<strong>FortiGate</strong>-5000 series)<br />

Blades (<strong>FortiGate</strong>-5000 chassis slots)<br />

Temperature<br />

Indicates if the temperature sensors for the module in each slot are<br />

detecting a temperature within an acceptable range. Good indicates<br />

that all monitored temperatures are within acceptable ranges. Alarm<br />

indicates that a monitored temperature is too high (usually about<br />

75°C) or too low (below 10°C).<br />

You can mouse over the temperature indicator to view the<br />

temperatures being read by each sensor on the module. The mouse<br />

over display includes the name of the temperature sensor and the<br />

temperature reading.<br />

The temperatures that are displayed depend on the <strong>FortiGate</strong> or<br />

FortiSwitch module. For example:<br />

For <strong>FortiGate</strong>-5005FA2 modules:<br />

• In<strong>com</strong>ing Air-Flow: 37°C<br />

• CPU Board Temp: 49°C<br />

• CPU1 Temp: 65°C<br />

• CPU2 Temp: 66°C<br />

For <strong>FortiGate</strong>-5001SX and <strong>FortiGate</strong>-5001FA2 modules:<br />

• TEMP1: 37°C<br />

• TEMP2: 30°C<br />

And for FortiSwitch-5003 modules:<br />

• Baseboard Temp: 35°C<br />

• Board (BRD) Top Temp: 33°C<br />

• BRD Bottom Temp: 33°C<br />

• BRD Center Temp: 38°C<br />

<strong>FortiGate</strong> Version 3.0 MR5 <strong>Administration</strong> <strong>Guide</strong><br />