IMA Level-1<br />

• LRUs re-packaged as LRMs in cabinet(s):<br />

� several types of st<strong>and</strong>ardized I/O modules (mix<br />

of analog/discrete/digital)<br />

� external input data-concentrators<br />

� st<strong>and</strong>ard computational module<br />

� integration only of power-supplies (shared)<br />

� no functional integration (LRUs mapped 1:1)<br />

� no new interactions (certification!)<br />

� ARINC-429 links between LRMs retained<br />

� ARINC-429 links between “cabinets”<br />

91<br />

©1995-1997 F.M.G. Dörenberg