APPENDIX 1/5: TESTING TO BE CARRIED OUT BY THE CONTRACTOR (CONTINUED)<br />

Clause Work, Goods or Materials Test Frequency of Testing Test Certificate Comments<br />

Series 3000<br />

3001 General Inspection Reports as<br />

required in Appendix 30/1<br />

3005 Grass seeding,<br />

Rate of spread of fertilizer<br />

1 per 1000 square<br />

Wildflower seeding and<br />

metres<br />

turfing<br />

Rate of spread of seeding<br />

1 per 1000 square<br />

††<br />

metres<br />

Chemical analysis of fertilizer<br />

1 per source<br />

Grass seed germination and purity<br />

1 per source and mix<br />

Required prior to<br />

†<br />

(Official Seed Testing Station<br />

variety<br />

sowing<br />

tests)<br />

1 Unless otherwise stated above, all sampling and testing in this Appendix shall be by the<br />

Contractor.<br />

2 Tests comparable to those specified in this Appendix will be necessary for any equivalent work,<br />

goods or materials proposed by the Contractor (See sub-Clause 105.4).<br />

3 (11/03) (N) indicates that a UKAS or equivalent accredited laboratory sampling and test report or<br />

certificate is required.<br />

4 Unless otherwise shown in this Appendix tests for work, goods or materials as scheduled under<br />

any one Clause are required for all such work, goods or materials in the Works.<br />

5 Cube strength tests are not required for concrete complying with Clause 2602.<br />

6 Unless otherwise shown in this Appendix test certificates for work, goods or materials as<br />

scheduled under any one Clause are required for all such work, goods or materials in the Works.<br />