DRAWINGS<br />

A Check List for Steelwork Sub-Contractor<br />

Clause<br />

Requirement<br />

Steelwork Details:<br />

Indicate all member sizes and weights.<br />

Provide full setting out dimensions on all Plans,<br />

Cross-sections & Elevations.<br />

Provide setting out plan for holding down bolts.<br />

Provide Cross-sections/Elevations on each grid<br />

line.<br />

Provide details of all bolted and welded<br />

connections.<br />

Add a General Note to the GA Drawings detailing<br />

anti-corrosion protection system.<br />

Indicate on GA Drawings fire protection system to<br />

be applied to all steel members<br />

Erection Precautions:<br />

Add a General Note to the GA Drawings to<br />

ensure that a Schedule of all High Strength<br />

Friction Grip Bolts used on the project.<br />

Indicate on drawings the location and type of any<br />

temporary bracing which may be required for the<br />

stability of the bare steel frame. These additional<br />

braces shall ensure the stability of the partially<br />

clad building prior to the erection of all roof and<br />

vertical bracing etc.<br />

Steel:<br />

List on GA Drawings the grades of steel to be<br />

used on the project.<br />

1802SR<br />

PROTECTION OF STEELWORK AGAINST CORROSION<br />

METAL COATINGS AND ANTI-CORROSIVE PAINT TREATMENTS<br />

(a)<br />

Galvanising<br />

Galvanising treatment shall be carried out in accordance with the<br />

requirements of BS EN ISO 1461:1999 "Specification for Hot-dip<br />

Galvanised Coatings". The metal coating thickness shall be not<br />

less than 85 microns (610 grams per square metre).<br />