DRAWINGS<br />
A Check List for Steelwork Sub-Contractor<br />
Clause<br />
Requirement<br />
Steelwork Details:<br />
Indicate all member sizes and weights.<br />
Provide full setting out dimensions on all Plans,<br />
Cross-sections & Elevations.<br />
Provide setting out plan for holding down bolts.<br />
Provide Cross-sections/Elevations on each grid<br />
line.<br />
Provide details of all bolted and welded<br />
connections.<br />
Add a General Note to the GA Drawings detailing<br />
anti-corrosion protection system.<br />
Indicate on GA Drawings fire protection system to<br />
be applied to all steel members<br />
Erection Precautions:<br />
Add a General Note to the GA Drawings to<br />
ensure that a Schedule of all High Strength<br />
Friction Grip Bolts used on the project.<br />
Indicate on drawings the location and type of any<br />
temporary bracing which may be required for the<br />
stability of the bare steel frame. These additional<br />
braces shall ensure the stability of the partially<br />
clad building prior to the erection of all roof and<br />
vertical bracing etc.<br />
Steel:<br />
List on GA Drawings the grades of steel to be<br />
used on the project.<br />
1802SR<br />
PROTECTION OF STEELWORK AGAINST CORROSION<br />
METAL COATINGS AND ANTI-CORROSIVE PAINT TREATMENTS<br />
(a)<br />
Galvanising<br />
Galvanising treatment shall be carried out in accordance with the<br />
requirements of BS EN ISO 1461:1999 "Specification for Hot-dip<br />
Galvanised Coatings". The metal coating thickness shall be not<br />
less than 85 microns (610 grams per square metre).<br />
78