Hills Cement Co. Limited.<br />

6. Compressor <strong>Control</strong>s<br />

Start/stop, load/unload, throttling, multi-step, variable speed and<br />

network controls are options for compressor controls and described<br />

below:<br />

• Start/stop (on/off) is the simplest control available and can be applied to<br />

reciprocating or rotary screw compressors. They are used for applications<br />

with very low duty cycles. Applications with frequent cycling will cause the<br />

motor to overheat.<br />

• Load/unload control, or constant speed control, allows the motor to<br />

run continuously but unloads the compressor when the discharge<br />

pressure is adequate. In most cases, unloaded rotary screw compressors<br />

still consume 15 to 35% of full-load power while delivering no useful work.<br />

Hence, load/unload controls can be inefficient.<br />

• Modulating or throttling controls allow the output of a compressor to be<br />

varied to meet flow requirements by closing down the inlet valve and<br />

restricting inlet air to the compressor. Throttling controls are applied to<br />

centrifugal and rotary screw compressors. Changing the compressor<br />

control from on/zero/off to a variable speed control can save up to 8% per<br />

year.<br />

Heat Recovery for Water Preheating<br />

As much as 80 to 93% of the electrical energy used by an Industrial air<br />

compressor is converted into heat. In many cases, a heat recovery unit<br />

can recover 50 to 90% of this available thermal energy for space heating,<br />

industrial process heating, water heating, makeup air heating, boiler<br />

makeup water preheating, industrial drying, industrial cleaning processes,<br />

heat pumps, laundries or preheating aspirated air for oil burners.<br />

7. Lighting<br />

• Lighting <strong>Control</strong>s (manual and automatic controls)<br />

• Replace T-12 Tubes by T-8 Tubes<br />

• Replace Mercury Lights by Metal Halide or High Pressure Sodium Lights<br />

• Replace Metal Halide HID with High-Intensity Fluorescent Lights<br />

• Replace Magnetic Ballasts with Electronic Ballasts<br />

<strong>Pollution</strong> <strong>Control</strong> Consultants (India) Pvt. Ltd. 127