Hills Cement Co. Limited.<br />
Table-3.19 Equivalent Noise Levels in the Study Area (10 km radius)<br />
Time<br />
Noise Level Monitoring Station<br />
in Hrs Mynkre Umlong Umtyra Lumshnong Umshangiar Umrasong<br />
<br />
6:00 40.6 40.9 43.2 43.1 43.3 43.6<br />
8:00 46.2 44.5 46.5 45.1 44.2 45.4<br />
10:00 54.7 53.2 55.1 54.8 52.6 53.5<br />
12:00 50.3 50.5 51.3 51.1 49.6 50.2<br />
14:00 48.7 49.2 48.4 47.2 46.7 47.3<br />
16:00 44.8 47.4 45.3 45.1 44.8 46.2<br />
18:00 56.3 54.7 52.8 53.6 54.2 53.8<br />
20:00 45.1 48.3 46.6 47.1 45.9 47.5<br />
22:00 44.2 45.8 44.6 45.8 44.6 45.6<br />
00:00 43.6 44.7 43.8 45.1 44.1 45.2<br />
2:00 43.3 44.2 43.5 44.3 43.4 44.1<br />
4:00 43.2 43.5 43.2 44.3 43.1 43.9<br />
The noise levels values are well below the acceptable standard noise<br />
levels.<br />
H. Water Environment<br />
Assessment of baseline data on water environment includes<br />
• Identification of surface water sources<br />
• Identification of ground water sources<br />
• Collection of water samples<br />
• Analyzing water samples for physio-chemical and biological<br />
parameters<br />
Assessment of water quality in the study area includes the water quality<br />
testing and assessment per the Indian standard IS 10500 (drinking water<br />
standard). The locations of water sampling are shown in Fig 3.7 water<br />
samples from various locations in and around the lant site within 10 km<br />
radius were collected for assessment of the physico-chemical and<br />
bacteriological quality. Methodologies adopted for sampling and analysis<br />
were according to the IS methods.<br />
Field parameters such as pH, Temperature and Dissolved Oxygen were<br />
tested at site. The parameters thus analyzed were compared with IS<br />
10500. Details of water sampling locations are given in table below.<br />
<strong>Pollution</strong> <strong>Control</strong> Consultants (India) Pvt. Ltd. 66