05.07.2015 Views

chapter - 1 introduction - Meghalaya State Pollution Control Board

chapter - 1 introduction - Meghalaya State Pollution Control Board

chapter - 1 introduction - Meghalaya State Pollution Control Board

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Hills Cement Co. Limited.<br />

Table-3.19 Equivalent Noise Levels in the Study Area (10 km radius)<br />

Time<br />

Noise Level Monitoring Station<br />

in Hrs Mynkre Umlong Umtyra Lumshnong Umshangiar Umrasong<br />

<br />

6:00 40.6 40.9 43.2 43.1 43.3 43.6<br />

8:00 46.2 44.5 46.5 45.1 44.2 45.4<br />

10:00 54.7 53.2 55.1 54.8 52.6 53.5<br />

12:00 50.3 50.5 51.3 51.1 49.6 50.2<br />

14:00 48.7 49.2 48.4 47.2 46.7 47.3<br />

16:00 44.8 47.4 45.3 45.1 44.8 46.2<br />

18:00 56.3 54.7 52.8 53.6 54.2 53.8<br />

20:00 45.1 48.3 46.6 47.1 45.9 47.5<br />

22:00 44.2 45.8 44.6 45.8 44.6 45.6<br />

00:00 43.6 44.7 43.8 45.1 44.1 45.2<br />

2:00 43.3 44.2 43.5 44.3 43.4 44.1<br />

4:00 43.2 43.5 43.2 44.3 43.1 43.9<br />

The noise levels values are well below the acceptable standard noise<br />

levels.<br />

H. Water Environment<br />

Assessment of baseline data on water environment includes<br />

• Identification of surface water sources<br />

• Identification of ground water sources<br />

• Collection of water samples<br />

• Analyzing water samples for physio-chemical and biological<br />

parameters<br />

Assessment of water quality in the study area includes the water quality<br />

testing and assessment per the Indian standard IS 10500 (drinking water<br />

standard). The locations of water sampling are shown in Fig 3.7 water<br />

samples from various locations in and around the lant site within 10 km<br />

radius were collected for assessment of the physico-chemical and<br />

bacteriological quality. Methodologies adopted for sampling and analysis<br />

were according to the IS methods.<br />

Field parameters such as pH, Temperature and Dissolved Oxygen were<br />

tested at site. The parameters thus analyzed were compared with IS<br />

10500. Details of water sampling locations are given in table below.<br />

<strong>Pollution</strong> <strong>Control</strong> Consultants (India) Pvt. Ltd. 66

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!