11.07.2015 Views

Swift Owner's Handbook - Swift Group

Swift Owner's Handbook - Swift Group

Swift Owner's Handbook - Swift Group

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

ElectricsSUPPORT SERVICEPLUG-IN SYSTEMS LIMITED PROVIDE ANON-CALL SERVICE FOR WARRANTY ORNON-WARRANTY REPAIRS.IF YOU WISH TO TAKE ADVANTAGE OFTHIS SERVICE FOR PLUG-IN-SYSTEMSONLYTelephone (01482) 652523 and ask forPRODUCT SUPPORT SERVICE.HABITATION RELAYTo conform with European Safety Standards(EMC) all caravans have been equipped witha habitation relay.This relay is actuated when the 12N/12Splugs are connected to the car’s sockets andthe car ignition is turned on.The relay automatically isolates all 12Vequipment within the caravan, excluding thefridge’s 12V power supply, from the car.GENERATOR GUIDELINES• Lack of regular servicing can be thecause of most generator problems,gensets under 2kW are mainly dependenton engine speed for output frequencyand voltage, poor or no servicing maycause the engine speed governor to runthe genset engine too fast. Thereforefrequency and output voltage can riseabove the specification of the machinedata plate i.e. 240v at 50Hz, this may40cause damage to electrical/electronicequipment (such as battery chargers).• A generator should always be run for afew minutes prior to connection with thecaravan or motorhome electrics, to allowit to warm up and the output to settle to asteady level.• The AC output of generators is oftenderived from an AC alternator, rectified toDC then inverted back to AC. In essencethis means the output sinewave may notbe very smooth and may not runsophisticated electronics efficiently. Someof the new wave of gensets are moresophisticated in their production of asinewave output and are more suited torun electronic equipment.• If in doubt consult your genset dealer ormanufacturer for advice.ESM2000The ESM2000 electrical Supply Module is a240 volt ac and 12 volt dc power controlunit. It provides all the necessary featuresfor control of the electrics in a caravan. Theunit provides the following features:Mains 240v ac - MAINS MODULEwithEARTH LEAKAGE PROTECTIONOVERCURRENT PROTECTION (RCD)REVERSE POLARITY INDICATION12 volt dc - FULLY AUTOMATICTRANSFORMER/CHARGERwith OVERCURRENT PROTECTIONSHORT CIRCUIT PROTECTION- SWITCH & FUSE MODULEwith BATTERY CHANGEOVER SWITCHCHARGER ON/OFF SWITCH8 FUSED DC OUTPUT CIRCUITSUNIT DESCRIPTIONMains ModuleThe ESM2000 is designed to operate on amains supply of 207-253 volts ac (making itideal for use with low continental voltages).The 40 amp RCD (Residual Current Device)gives protection against earth faults and alsoacts as the main switch. The mains modulealso has three MCR's (Miniature CircuitBreakers) which are basically resetablemains fuses, to protect against overcurrent.Allocation of the MCB's is as follows:MCB1 - SOCKETS/FAN MASTER (if fitted)MCB2 - CASCADE/LIGHTS (if fitted)MCB3 - FRIDGE/CHARGERUsing a generatorWhen using a generator in conjunction withthe ESM2000 the following must beobserved, failure to do so may result indamage to the unit:

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!