11.07.2015 Views

Swift Owner's Handbook - Swift Group

Swift Owner's Handbook - Swift Group

Swift Owner's Handbook - Swift Group

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Fitted EquipmentWhen using electric heating the caravantemperature is regulated by the thermostatmounted at the top of the installation box butwhen using the gas heating the temperatureis controlled by the gas heater thermostat.The night setting is a 1kW convector heatersetting. In the summer the fan may beoperated without any heat input to distributecool air.The Fanmaster has an air deflector allowingthe majority of air to be directed down onefan outlet. For example, down the longestducting run. This may have been preset oninstallation.The duct outlets are generally of the butterflytype and may be opened or closed byadjusting the butterfly valves. Twisting thedisc in its housing directs the flow in thedirection required. One outlet on each leg ofthe duct layout must be kept open.ServicingIn order to ensure that your heater continuesto operate effectively, you will need toarrange for it to be serviced at least once ayear by a competent and trained serviceengineer. By law no one is permitted to dealwith the installation and servicing of gasappliances unless they have provencompetence. Contact your nearestauthorised caravan distributor if service orrepair is required.FANMASTER CONTROLLER OPERATIONS - SLIDE SWITCH ON HEATER TOP(R.H. INSTALLATION)POSITION OPERATION (without gas) OPERATION (with gas)0 Off Gas convectorManual fan speed - Temperature Blown hot air distribution1 slider governs the fan speed.For cool air distribution.1kW electric convector heating,Electric and Gas convection, but a high gas2 no fan. Temperature slider heater output will inhibit the electric heatingselects desired room temperature to maintain safe operating temperatures.1kW electric fan heating,Electric and Gas blown distribution. Fan3 fan remains slow. speed adjusts automatically based onoutlet temperature.42kW electric fan heating. Fanautomatically adjusts speed to suit.Electric and gas blown distribution. Fanspeed adjusts automatically.FANMASTER CONTROLLER OPERATIONS - WALLSWITCH CONTROL(L.H. INSTALLATION)POSITION OPERATION (without gas) OPERATION (with gas)0 Off Gas convectorManual fan speed - Wall switchBlown hot air distribution12knob governs the fan speed.For cool air distribution.Automatic fan speed, temperatureof heater governs fan speed.Blown hot air distribution with automaticfan speed control.1kW electric convector heating, no Electric and Gas blown distribution. Fan3 fan. Wall switch knob selects speed adjusts automatically based ondesired room temperature.outlet temperature.41kW electric fan heating, fanElectric and gas blown distribution. Fanremains slow.speed adjusts automatically.52kW electric fan heating. Fanautomatically adjusts speed to suit.60

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!