11.07.2015 Views

Swift Owner's Handbook - Swift Group

Swift Owner's Handbook - Swift Group

Swift Owner's Handbook - Swift Group

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Fitted EquipmentOne outlet on each leg of the air ductinglayout must be kept open at all times.Note:Mains hook-up is needed for positions 2, 3and 4, the current consumption will beapproximately 4 amps for positions 2 & 3 andapproximately 8 amps for position 4.If you suspect that your mains hook-up isinadequate to supply the 8 amps required forposition 4 in addition to your existing mainsload, then for initial warm-up, use the Carvergas heater on a high setting and theFanmaster on the position 1 setting.FANMASTER CONTROLLER OPERATIONS (Fig. 2)POSITION OPERATION (without gas) OPERATION (with gas)0 Off Gas convectorManual fan speed - Temperature Blown hot air distribution1 slider governs the fan speed.For cool air distribution.1kW electric convector heating,Electric and Gas convection, but a high gas2 no fan. Temperature slider heater output will inhibit the electricselects desired roomheating to maintain safe operatingtemperature.temperatures.1kW electric fan heating,Electric and Gas blown distribution. Fan3 fan remains slow. speed adjusts automatically based onoutlet temperature.42kW electric fan heating. Fanautomatically adjusts speed to suit.Electric and gas blown distribution. Fanspeed adjusts automatically.Fig. 4When comfortable change to either positions2 or 3 and turn the gas heater off.Typical mains current consumption is:Carver Cascade 2 water heaterTravelling kettleBattery charger623.6A approx.3.2A approx.1.0A approx.Portable colour TV60w light bulbFanmaster on position 4Fanmaster on position 2 or 30.3A approx.0.3A approx.8.3A approx.4.2A approx.The normal mains supply to UK sites arerated at 16A but some sites have only a 10Acapacity.ServicingIn order to ensure that your heater continuesto operate effectively, you will need toarrange for it to be serviced at least once ayear by a competent and trained serviceengineer. By law no-one is permitted to dealwith the installation and servicing of gasappliances unless they have provencompetence. Contact your nearest caravandistributor if service or repair is required.SafetyTo prevent over-heating of the electricelements at least one warm air outlet mustbe open at all times. It is recommended thatone outlet should be of the non-closabletype and not a butterfly.If all the outlets are closed the self-holdthermal trip will switch off the power to theelements. If this happens, open the outlets,switch the heater power off and wait until theunit has cooled down, the unit will then resetitself.Make sure that clothing etc. is kept clear ofthe back of the heater.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!