11.07.2015 Views

Swift Owner's Handbook - Swift Group

Swift Owner's Handbook - Swift Group

Swift Owner's Handbook - Swift Group

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Fitted EquipmentThe heater must only to be connected tothe mains via the integrated 3 wayconnector provided.If the cover to the electrical heater isremoved the mains must be disconnected.Important Note:Any interference with and modification to theheater may lead to serious functionalproblems. Changes to the gas or exhaustcomponents can pose a direct risk to life,and Primus declines all responsibility in theevent of such changes being made.1. The guarantee lapses with immediateeffect if any work is performed other thanby a specialist.2. Use only Primus original spare parts.3. Only a specialist must carry out repairs.4. The small O-ring must be replaced if theexhaust outlet is dismantled.5. The gas installation and any tests mustconform to national requirements.6. Keep the exhaust outlet and the air inletfree from dirt, snow and ice.7. The heater must not be in use whenrefuelling and when in the garage.8. The domestic hot water heater isequipped with a safety valve, whichopens at approx. 3 bar. (Any drainagetakes place via a drainpipe through thefloor.)9. The heater must be run with water/glycol(60/40) in the system at all times. If theheater is operated dry, it will normally bestopped by the operating thermostat. Thethermostat will close after cooling, andthe heater will then function normallyprovided that water is present in thesystem. If the operating thermostat failsto trip for any reason in the event of thesystem overheating, the heater will bestopped by a built-in secondary overheatthermostat. A red LED on the controlpanel indicates this. The electricalcartridge has a separate overheatingprotection.Technical DataAQWE6GasI3BP /I3+Working gas pressure30 mbar/28-30/37mbar IWall exhaustYesVolume Boiler9 litHeating-up time hot water20 minutesMax D: H: W. pressure2,8 barLength x Width x Height 500 x 400 x 300Weight (without water)15,1 kgNumber of steps in gas burner 3Max power2.6/5.0/7.0 kWTechnical DataAQWE6Max gas consumption210/420/580 g/hNumber of steeps electric heater 3Output electrical power1/2/3 kWWorking voltage12 V = /230 V ACElectric power consumption 12 V 300/400/750 mAElectric power consumption 230 V 5/10/16 AExhaust length max.45-mmExhaust diameter54,3-mmAir inlet diameter88,3-mm66

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!