11.07.2015 Views

Swift Owner's Handbook - Swift Group

Swift Owner's Handbook - Swift Group

Swift Owner's Handbook - Swift Group

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Fitted EquipmentEquipment SpecificationFor details on type of equipment fitted inyour caravan, please refer to the SalesBrochure or Dealer.IMPORTANTTo maximise the use and life of all fittedequipment in your caravan it is essential thatany accompanying manufacturers’ literatureis read fully. All recommended maintenanceand preparation procedures should befollowed. The information provided in thishandbook is only intended as a guide. If inany doubt consult your manufacturerappointed dealer, particularly beforeattempting to install EXTRA EQUIPMENT.WHALE WATER PUMPThe Whale pump is a non self primingintermittently rated centrifugal pump whichdraws approximately two amperes from a 12volt battery and therefore maximumcontinuous operation should not exceed 15minutes.The pump should not be run without waterand should not be used to pump water of atemperature above 60°C.SHURFLO WATER PUMPFresh water is supplied to the caravan by aShurflo pump. This pump is a completelysealed unit designed for intermittent use andis self-priming.48Fig. AGREENYELLOWREDFig. BCASCADE 2 GE RAPIDE WATERHEATEROPERATING INSTRUCTIONSThe gas side of the Cascade 2 GE RapideWater Heater is operated by the controller onthe integrated control panel (Fig. A) exceptfor models with the separate control panelswhich are operated from the wall switch(Fig. B).Before switching on the gas burner or themains immersion heater make sure that waterflows from the hot taps. This indicates thatthe water heater is full.TO OPERATE THE HEATER ON GAS1. Close the window near the Cascade cowlwhen the heater is running on gas.2. Check that the 12 volt supply isconnected and switched on. DO NOT usea battery charger as the only source ofsupply.3. To light the heater, press the ON button.A continuous green light indicates thatthe heater is working satisfactorily.4. To switch the heater OFF press the OFFbutton.Light IndicationGreen. The heater is working satisfactorily.Green & Yellow. The DC voltage is below the10.5 volts that is required to operate theheater. Recharge the battery.Green & Red. The heater has failed to igniteor that the heater has gone to safety shutdown. This is usually due to failure of the gassupply or air in the gas system after fitting anew cylinder. Switch the heater off and WAIT3 MINUTES before attempting to relight theheater. If air in the gas system is the problemseveral attempts may be necessary beforethe heater ignites.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!