154 Input/Output <strong>Instructions</strong> (MSG, GSV, SSV, IOT)Block-Transfer Error CodesThese are the <strong>Logix5000</strong> block-transfer specific error codes.Error Code(Hex)00D0DescriptionThe scanner did not receive a block-transfer response from the block-transfer modulewithin 3.5 seconds of the requestDisplay In Softwareunknown error00D1 The checksum from the read response did not match the checksum of the data stream unknown error00D2The scanner requested either a read or write but the block-transfer module responded with unknown errorthe opposite00D3The scanner requested a length and the block-transfer module responded with aunknown errordifferent length00D6The scanner received a response from the block-transfer module indicating the write unknown errorrequest failed00EAThe scanner was not configured to communicate with the rack that would contain this unknown errorblock-transfer module00EB The logical slot specified is not available for the given rack size unknown error00ECThere is currently a block-transfer request in progress and a response is required before unknown erroranother request can begin00EDThe size of the block-transfer request is not consistent with valid block-transferunknown errorsize requests00EEThe type of block-transfer request is not consistent with the expected BT_READunknown erroror BT_WRITE00EFThe scanner was unable to find an available slot in the block-transfer table tounknown erroraccommodate the block-transfer request00F0The scanner received a request to reset the remote I/O channels while there were unknown erroroutstanding block-transfers00F3 Queues for remote block-transfers are full unknown error00F5 No communication channels are configured for the requested rack or slot unknown error00F6 No communication channels are configured for remote I/O unknown error00F7 The block-transfer timeout, set in the instruction, timed out before completion unknown error00F8 Error in block-transfer protocol - unsolicited block-transfer unknown error00F9 Block-transfer data was lost due to a bad communication channel unknown error00FAThe block-transfer module requested a different length than the associatedunknown errorblock-transfer instruction00FB The checksum of the block-transfer read data was wrong unknown error00FCThere was an invalid transfer of block-transfer write data between the adapter and the unknown errorblock-transfer module00FDThe size of the block-transfer plus the size of the index in the block-transfer data table wasgreater than the size of the block-transfer data table fileunknown errorPublication 1756-RM003I-EN-P - January 2007

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!