Input/Output <strong>Instructions</strong> (MSG, GSV, SSV, IOT) 169Specify a Communication Method Or Module AddressUse the following table to select a communication method or moduleaddress for the message.If The Destination Device Is a Then Select And Specify<strong>Logix5000</strong> controller CIP no other specifications requiredPLC-5 controller over anEtherNet/IP networkPLC-5 controller over aControlNet networkSLC 5/05 controllerPLC-5 controller over a DH+networkSLC controller over a DH+networkDH+ Channel: Channel A or B of the 1756-DHRIO module thatis connected to the DH+ networkSource Link:Link ID assigned to the backplane of thecontroller in the routing table of the 1756-DHRIOmodule. (The source node in the routing table isautomatically the slot number of the controller.)PLC-3 processor Destination Link Link ID of the remote DH+ link where the targetdevice residesPLC-2 processor Destination Node: Station address of the target device, in octalIf there is only one DH+ link and you did not use the RSLinx software toconfigure the DH/RIO module for remote links, specify 0 for both theSource Link and the Destination Link.Application on a workstationthat is receiving an unsolicitedmessage routed over anEtherNet/IP or ControlNetnetwork through RSLinxblock transfer module over auniversal remote I/O networkblock transfer module over aControlNet networkCIP with Source ID(This lets the applicationreceive data from acontroller.)Source Link:Remote ID of the topic in RSLinx softwareDestination Link: Virtual Link ID set up in RSLinx (0-65535)Destination Node: Destination ID (0-77 octal) provided by theapplication to RSLinx. For a DDE topic in RSLinx,use 77.The slot number of the ControlLogix controller is used as the SourceNode.RIO Channel: Channel A or B of the 1756-DHRIO module thatis connected to the RIO networkRackRack number (octal) of the moduleGroupGroup number of the moduleSlotSlot number that the module is inControlNet Slot Slot number that the module is inPublication 1756-RM003I-EN-P - January 2007

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!