12.07.2015 Views

Asahipak - Hplc.eu

Asahipak - Hplc.eu

Asahipak - Hplc.eu

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Standard analysiscolumnsOrganic SEC (GPC) columns(General Analysis) : THF, chloroformFeaturesKF-800, K-800Standard organic solvent SEC (GPC) columnSupports a wide range of applications from low to high-molecular-weightcompoundsPreparativeColumnsp.86, 87Standard columns52Organic SEC (GPC) columns (General Analysis) : THF, chloroformKF-800 series : Shipping solvent tetrahydrofuran(THF)Product CodeF6028010F6028020F6028025F6028030F6027030F6028040F6027040F6028050F6027050F6028060F6028090F6027060F6028070F6027070F6700300F6709350F6028110F6028120F6028125F6028130F6028194F6028140F6028195F6028150F6028196F6028160F6028190F6028197F6028170F6028198F6700401F6709450Product NameGPC KF-801GPC KF-802GPC KF-802.5GPC KF-803GPC KF-803LGPC KF-804GPC KF-804LGPC KF-805GPC KF-805LGPC KF-806GPC KF-806MGPC KF-806LGPC KF-807GPC KF-807LGPC KF-GGPC KF-800DK-800 series : Shipping solvent chloroformProduct CodeProduct NameGPC K-801GPC K-802GPC K-802.5GPC K-803GPC K-803LGPC K-804GPC K-804LGPC K-805GPC K-805LGPC K-806GPC K-806MGPC K-806LGPC K-807GPC K-807LGPC K-GGPC K-800DPlate Number(TP/column)≥ 18,000≥ 18,000≥ 18,000≥ 18,000≥ 18,000≥ 18,000≥ 18,000≥ 11,000≥ 11,000≥ 11,000≥ 13,000≥ 11,000≥ 6,000≥ 6,000(guard column)(solvent-peak separation column)Plate Number(TP/column)≥ 18,000≥ 18,000≥ 18,000≥ 18,000≥ 18,000≥ 18,000≥ 18,000≥ 11,000≥ 11,000≥ 11,000≥ 13,000≥ 11,000≥ 6,000≥ 6,000(guard column)(solvent-peak separation column)Exclusion Limit(PS)1,5005,00020,00070,00070,000400,000400,0004,000,0004,000,000(20,000,000)*(20,000,000)*(20,000,000)*(200,000,000)*(200,000,000)*−−Exclusion Limit(PS)1,5005,00020,00070,00070,000400,000400,0004,000,0004,000,000(20,000,000)*(20,000,000)*(20,000,000)*(200,000,000)*(200,000,000)*−−Particle Size(μm)666667710101010101818810Particle Size(μm)666667710101010101818810* See page 54 for details of the solvent-peak separation columns. The columns with ‘L’or ‘M’ at the end of the column name aremixed-gel columns capable of a wide molecular weight distribution range of samples.MaximumPore SizeColumn Size(Å) (mm) I.D. x L50 8.0 × 300150 8.0 × 300300 8.0 × 300500 8.0 × 300500 8.0 × 3001,500 8.0 × 3001,500 8.0 × 3005,000 8.0 × 3005,000 8.0 × 30010,000 8.0 × 30010,000 8.0 × 30010,000 8.0 × 30020,000 8.0 × 30020,000 8.0 × 300−4.6 × 10−8.0 × 100*( )Estimated valueMaximumPore Size(Å)501503005005001,5001,5005,0005,00010,00010,00010,00020,00020,000−−Column Size(mm) I.D. x L8.0 × 3008.0 × 3008.0 × 3008.0 × 3008.0 × 3008.0 × 3008.0 × 3008.0 × 3008.0 × 3008.0 × 3008.0 × 3008.0 × 3008.0 × 3008.0 × 3004.6 × 108.0 × 100*( )Estimated valueMolecular weight range with polystyrene (eluent KF-800 series : THF, K-800 series : chloroform)Molecular weight (Polystyrene)10 10 2 10 3 10 4 10 5 10 6 10 7 10 8 10 9KF-, K-801KF-, K-802KF-, K-802.5KF-, K-803KF-, K-804KF-, K-805KF-, K-806KF-, K-807Molecular weight (Polystyrene)10 10 2 10 3 10 4 10 5 10 6 10 7 10 8 10 9KF-, K-803LKF-, K-804LKF-, K-805LKF-, K-806MKF-, K-806LKF-, K-807L*Contact Shodex or our distributors near you for customized columns.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!