12.07.2015 Views

Asahipak - Hplc.eu

Asahipak - Hplc.eu

Asahipak - Hplc.eu

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Standard analysiscolumnsOrganic SEC (GPC) columns :Rapid Analysis, High Performance AnalysisFeaturesKF-600Approximately half of the analysis time required with standard columnsThe amount of solvent used is reduced to about a thirdImproved applicability of solvent replacementKF-400HQAbout 1.5-times better separation performance than standard columns, with higher resolutionAbout 4-times better sensitivity than that of standard columns, supporting high sensitivity analysisThe amount of solvent used is reduced to about a thirdNews No.3, 10Improved applicability of solvent replacementRapid analysis downsized columnsKF-600 seriesUse of the KF-600 series with semi-micro type devices is recommended.56Product CodeProduct NamePlate Number(TP/column)Exclusion Limit(PS)Particle Size(μm)Maximum Pore Size(Å)Column Size(mm) I.D. x LOrganic SEC (GPC) columns : Rapid Analysis, High Performance AnalysisF6028091F6028092F6028093F6028094F6028095F6028096F6028097F6028098F6028099F6700300F6028111F6028112F6028114F6028116F6028118F6028119F6028122F6700300GPC KF-601GPC KF-602GPC KF-602.5GPC KF-603GPC KF-604GPC KF-605GPC KF-606GPC KF-606MGPC KF-607GPC KF-GGPC KF-401HQGPC KF-402HQGPC KF-402.5HQGPC KF-403HQGPC KF-404HQGPC KF-405LHQGPC KF-406LHQGPC KF-G≥ 17,000≥ 17,000≥ 17,000≥ 17,000≥ 16,000≥ 7,000≥ 7,000≥ 8,000≥ 5,000≥ 25,000≥ 25,000≥ 25,000≥ 25,000≥ 25,000≥ 10,000≥ 10,0001,5005,00020,00070,000400,0004,000,000(20,000,000)*(20,000,000)*(200,000,000)*−* The columns with ‘M’ at the end of the column names are mixed-gel columns capable of awide molecular weight distribution range of samples.High performance semi-micro columnsKF-400HQ seriesProduct CodeProduct Name(guard column)Plate Number(TP/column)(guard column)1,5005,00020,00070,000400,0004,000,000(20,000,000)*−* The columns with ‘L’ at the end of the column names are mixed-gel columns capable of awide molecular weight distribution range of samples.Molecular weight range with polystyrene (eluent : THF)333331010101883333310108501503005001,5005,00010,00010,00020,000−501503005001,5005,00010,000−6.0 × 1506.0 × 1506.0 × 1506.0 × 1506.0 × 1506.0 × 1506.0 × 1506.0 × 1506.0 × 1504.6 × 10Shipping solvent : tetrahydrofuran(THF)*( )Estimated valueUse of the KF-400HQ series with semi-micro type devices is recommended.Exclusion Limit(PS)Particle Size(μm)Maximum Pore Size(Å)Column Size(mm) I.D. x L4.6 × 2504.6 × 2504.6 × 2504.6 × 2504.6 × 2504.6 × 2504.6 × 2504.6 × 10Shipping solvent : tetrahydrofuran(THF)*( )Estimated valueMolecular weight (Polystyrene)10 10 2 10 3 10 4 10 5 10 6 10 7 10 8 10 9KF-601KF-602KF-602.5KF-603KF-604KF-605KF-606Molecular weight (Polystyrene)10 10 2 10 3 10 4 10 5 10 6 10 7 10 8 10 9KF-401HQKF-402HQKF-402.5HQKF-403HQKF-404HQKF-405LHQKF-406LHQKF-607KF-606MCalibrationStandardsSee page 63 forCalibration Standards*Contact Shodex or our distributors near you for customized columns.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!