12.07.2015 Views

Asahipak - Hplc.eu

Asahipak - Hplc.eu

Asahipak - Hplc.eu

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Instruments Electric Conductivity Detector Dissolved Gas Removal Devices92NEWProduct CodeModelMeasurement methodMeasurement limitMeasurement rangeLinearity rangeResponseAuto zero limitBaseline shiftIntegrator outputRecorder outputExternal inputExternal OutputCell Temperature controlCommunication portCell volumePressure ratingWetted materialsDimension, WeightPower source,Power consumptionElectric Conductivity DetectorShodex CD−200The electric conductivity detector is designed for ion chromatography. It is recommended for anion orcation analysis in aqueous solution.FeaturesWith use of the built-in double temperature control cell, thisdetector enables highly sensitive measurement.The detector supports a wide range of measurement and isusable for ion chromatography with or without suppressormethod.F5515010CD-200Two-electrode system0~600mS/m (0~6mS/cm)0.0025~5.12mS/m, 0.025~51.2mS/m, 0.25~512mS/m600mS/m0.1, 0.25, 0.5, 1.0, 1.5, 2, 3, 6secSame as measurement limitRange;0~2mS/m, Resolution;0.01mS/m0~1V (Sensitivity:200, 20, 2mV/mS/m)0~10mV/FSZERO INMARKER INREADY(TEMPERATURE STABILIZED)LEAKERROR(ROM,RAM,PARAMETER,SENSOR,OVER HEAT,ZERO OVER)MARKER OUTOFF, 30~50˚C (1˚C step), 77˚C Temp. fuseUSB2.5μL1MPaStainless steel 316, Teflon, PEEKW260 x D400 x H150 (mm), ca. 8kgAC 100~240V±10%,200VA max(OUT)HeatexchangerDissolved Gas Removal DevicesDEGASSER ERC-3215α, 3415αThe ERC-3000α series efficiently remove dissolved gases in the eluent.Degassing principleA special synthetic resin membrane (degassing membrane) isused to selectively remove dissolved gasses ; using thecharastaristics of the small molecular size of the dissolved gaswith high mobility and affinity to the membrane.FeaturesPressure sensor and leak monitor assure a high degree of safety.Dead volume is minimized to 7 ml/flow channel.Any pump can be used since differential pressure is low.Continuous degassing mode aids eluent preparation forhigh-sensitivity analysis.EMC and LVD compliance, with CE marking.Principle of measurement of the electric conductivity detectorEluent(IN)ElectrodeSpacerElectrodeExternal cylinder(temperature control at presettemperature - 5°C)Internal cylinder(temperature control at presettemperature)Current/voltageconvertercircuitAC voltagegeneratorSynchronousrectifier circuitSignalprocessingcircuitElectricconductivitysignalProduct CodeModelSolvent ChannelsDegassingcapacityInternal volumeMax. Flow RateExternal outputDimensionsPower sourceFunctions,DisplaysWeightY4617000ERC-3215α2 channelsY4617004ERC-3415α4 channelsWhen ion-exchanged water saturated with air at 25˚C is put through at aflow rate of 3 mL/min, no bubble is observed at the outlet of the apparatus.(Measured dissolved oxygen level at the outlet: 2 ppm at flow rate of 3 mL/min)7mL/Channel20mL/min for each channel (Eluent : 25˚C Pure water)An open connector signal is delivered to the external outputsignal terminal, when "PRES" and "LEAK" LEDs lights are on.W71 x D310 x H136 (mm)AC100V~AC240V, 50/60Hz• Power On/Off display : "POWER" LED lights, when the power is supplied.• Status monitoring function : "READY" LED lights, when the internalpressure in the vacuum chamber is below a predetermined limit.• Pressure monitoring function : "PRES" LED lights, when the internalpressure in the vacuum chamber does not reach a predetermined levelwithin a predetermined time.• Leak monitor : "LEAK" LED lights, when the liquid leaks in the apparatus.• Self cleaning : The vacuum line is cleaned by air suction.• Vacuum pump operation switching function:NORM. : Controlled operation in normal runCONT. : Continuous operation in case of high degree of degassingca. 5.1kgca. 5.5kgVacuum chamberMembrane degasserFeed pump tooutletEluentPressuresensorVacuum pumpControlboardThree-waysolenoid valve•In addition to this product, various degassers are availableincluding the six-flow channel type and the high flow ratetype. For details, please contact Shodex or our distributorsnear you.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!