12.07.2015 Views

Vectra Genisys Service Manual - DJO Global

Vectra Genisys Service Manual - DJO Global

Vectra Genisys Service Manual - DJO Global

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

4- SPECIFICATIONS<strong>Vectra</strong> <strong>Genisys</strong>®/Intelect Legend XT®/ Intelect® Vet Therapy Systems4.3 ULTRASOUND SPECIFICATIONSThis section provides the necessary UltrasoundSpecifications to aid in troubleshooting the<strong>Vectra</strong> <strong>Genisys</strong>, Intelect Legend XT or Intelect VetUltrasound PC Board and Applicators.1 cm 2 2 cm2 (STANDARD)5 cm 2Refer to these specifications as necessary whentroubleshooting the Ultrasound PC Board andApplicators.10 cm 2UltrasoundFrequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 MHz, ± 5%; 3.3 MHz, ±5%Duty Cycles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10%, 20%, 50%, and ContinuousPulse Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 HzPulse Duration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 mSec, ±20%; 2 mSec, ±20%, and 5 mSec, ±20%Output Power10 cm2 Crystal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0-20 Watts at 1 MHz and 0-10 Watts at 3.3 MHz5 cm2 Crystal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0-10 Watts, 1 and 3.3 MHz2 cm2 Crystal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-4 Watts, 1 and 3.3 MHz1 cm2 Crystal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-2 Watts 3.3 MHz OnlyAmplitude . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 to 2.5 w/cm2 in continuous mode,0-3 w/cm2 in pulsed modesOutput accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 20% above 10% of maximumTemporal Peak to Average Ratios: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:1, ± 20%, at 50% Duty Cycle5:1, ± 20%, at 20% Duty Cycle9:1, ± 20%, at 10% Duty CycleBeam Nonuniformity Ratio. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.0 : 1 maximumBeam Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CollimatingIPX0 Rating for Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .IPX0IPX7 Rating for Applicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .IPX7Effective Radiating Areas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 cm 2 Crystal: 6.8 cm 2 – 10 cm 25 cm 2 Crystal: 3.5 cm 2 – 5 cm 22 cm 2 Crystal: 1.4 cm 2 – 2 cm 21 cm 2 Crystal: 0.7 cm 2 – 1 cm 2Treatment Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-30 MinutesHead Warming FeatureThe Head Warming feature of an <strong>Vectra</strong> <strong>Genisys</strong>, Intelect Legend XT or Intelect Vet Combination Therapy Systemutilizes Ultrasound output resulting in warming of the Sound Head to increase patient comfort.With Head Warming enabled, ultrasound is emitted without pressing the Start button. The Applicator LED will notilluminate during the Head Warming period. US Channel will indicate "Head Warming".Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0 - 50% Cycling of maximum powerFrequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.3 MhzSound Head Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 °F - 110 °F (29.4 °C - 43.3 °C)24

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!