13.07.2015 Views

AlphaCom XE - Zenitel

AlphaCom XE - Zenitel

AlphaCom XE - Zenitel

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Hot-PlugAMC board statusSyncronisationAUX (not in use)FLASHOFFExchangeresetOFFSoftwarestartingREDStartuprunningAMBERNormaloperationGREENflashIncorrectNVRAMversionAMBERflashIndicatorsThe card has a number of LEDs to indicate the boardand Ethernet status.See section 12.4.1 for other possible Ethernet LEDindications.Reset initiatedREDOFFOFF OFF OFFCold start buttonLink status (Eth1)Tx/Rx (Eth1)Link status (Eth0)Tx/Rx (Eth0)Flash activity~FILTER BOARD0110RS232RS232/422/485USBEth1Eth0SignalgroundGNDLink UpGREENReceivedataGREENFuture useRCI1...6AlarminputsFrom APC boardSpeednegotiationGREENflashTransmitdataREDAPC boardP1P2P3P4P5P61...6ProgramsourcesA1A2A3A4A5A6Hot plugoutResetProgram preset volumeP1P2P3P4P5P6PROGRAMCONNECTION BOARDCONNECTION BOARDab 1 4cd25Flash1activityGREENFlash2activityREDFilter boardA filter and connection board, FBIP, must be inserted from the rear sideof the cabinet in the same card position as the AMC-IP card. This filterboard is not needed in <strong>AlphaCom</strong> <strong>XE</strong>1 or <strong>XE</strong>7 where all EMC filters andexternal connectors are integrated in the backplane.The USB connector is not supported in AMC-IP board 11 versions.2.2.8 APC - Program and Clock BoardThe APC Board is used in <strong>AlphaCom</strong> <strong>XE</strong>20 and <strong>XE</strong>26 to control thebackplane board clocking. It also controls the speed of the fans. Thisboard must be installed in position 26.It contains circuitry for 6 audio program feed channels with galvanicisolation. Each channel has separate input level controls.The card has 6 RCI alarm inputs which can be used for programmedactions. The inputs accept a closing contact referred to ground.A reset button is used to reset and restart the entire server. The resetLED on the AMC-IP board will turn red during reset.An APC connection kit 100 9503 000 needs to be purchased to connectalarm and audio sources. The kit contains a filter board, a connectionboard, and an interface cable.Further information is found in datasheet A100K10011.2.2.9 ASLT - Subscriber Line BoardTwo boards for 12 intercom subscribers are normally delivered with theserver. The maximum number of cards in one server is:<strong>AlphaCom</strong> <strong>XE</strong>7: 6 in positions 1-6<strong>AlphaCom</strong> <strong>XE</strong>20: 17 in positions 1, 8-23<strong>AlphaCom</strong> <strong>XE</strong>26: 23 in positions 1-23Each board contains circuitry for 6 subscriber connections and onemeasurement channel for voice switching control.The board provides 6 remote control software controlled outputs. Theline monitoring reports errors on all subscriber lines.Relay board1....6MRBD3 6123456RCO<strong>AlphaCom</strong> <strong>XE</strong>20/<strong>XE</strong>26Intercom stations and control outputs are connected to a connectionboard mounted on the server connection field.FILTER BOARD5/10mCONNECTION FIELD2 subscriber connection boards (100 9930 200) with 1.5 m connectioncables (100 9501 011) are delivered with the servers.5 m (100 9501 021) and 10 m (100 9501 023) subscriber connectioncables with filter boards can be purchased separately if the distributionA100K10805<strong>AlphaCom</strong> <strong>XE</strong> - Installation, Configuration & Operation13

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!