Receptor unit (for ceiling type) assembly procedure<br />

1 Attach the receptor unit onto the indoor main unit as shown in the figure below.<br />

1. Remove the air-intake grille and the side cover.<br />

To remove the side cover, remove the fixing screw each on the left and the right and pull the side cover towards you.<br />

(Refer to the installation Manual supplied with the indoor main unit.)<br />

2. Remove the Decorative grille (component on which the brand name is shown) to the right on the air-blow opening. (Fixed with three tabs.)<br />

(There is a gap at the rear center of the decorative grille. Insert the tip of a slotted screwdriver, etc., 2 to 3mm into the gap and pry of the decorative<br />

grille to remove.)<br />

3. Draw out the cord of the receptor unit through the feed-through hole toward the side plate and attach the receptor unit onto the main unit.<br />

Hook the three tabs onto the receptor unit to attach the receptor unit on the main unit. (Press in the receptor unit until a click sound is heard.)<br />