12.4. Emergency operation<br />

When using the wireless remote control and losing the remote controller, emergency operation can be operated by pressing auto<br />

button in the receiver.<br />

• Press the auto button continuously within 5 seconds<br />

Press the auto button continuously within 5 seconds<br />

→ emergency operation<br />

• Press the auto button continuously for more than 5 seconds to less than 8 seconds<br />

→ cooling test operation<br />

• Press the auto button continuously for more than 8 seconds to less than 11 seconds<br />

→ cooling test operation<br />

Press the auto button continuously for more than 11 seconds to less than 16 seconds<br />

→ set remote controller address<br />

Press the auto button continuously for more than 16 seconds to less than 21 seconds<br />

→ remote controller address confirmation mode<br />

Press the auto button continuously for more than 21 seconds to less than 26 seconds<br />

→ change address of branch unit<br />

Press the auto button continuously for more than 26 seconds to less than 31 seconds<br />

→ individual change mode<br />

During the above each stage, finally press the SET button, then the operation mode can be decided.<br />

If there is an abnormality in the temperature thermistor (disconnect or shorted), indoor unit cannot be operated.<br />

If abnormality detected in the indoor or outdoor unit, turn off the main power supply and find the cause.<br />

Check the resistance of each thermistor of both indoor and outdoor units by referring the resistance table as follows.<br />

Thermistor resistance table<br />

Resistance value (kΩ)±5%<br />

Temperature Indoor Outdoor<br />

°C Room temperature Pipe temperature Discharge temperature Pipe temperature<br />

thermistor thermistor thermistor thermistor<br />

-20 158.5 211.3 528.3 47.9<br />

-10 87.5 116.7 291.8 27.1<br />

-5 66.1 88.2 220.5 20.7<br />

0 50.5 67.3 168.3 15.9<br />

5 38.9 51.9 129.8 12.4<br />

10 30.3 40.4 100.9 9.8<br />

15 23.8 31.7 79.2 7.7<br />

20 18.8 25.1 62.7 6.2<br />

25 15 20 50 5<br />

30 12.1 16.1 40.2 4<br />

40 8 10.6 26.5 2.7<br />

50 5.4 7.2 17.9 1.9<br />

60 3.7 5 12.4 1.3<br />