Resistance value (kΩ)±5%<br />
Temperature Indoor Outdoor<br />
°C Room temperature Pipe temperature Discharge temperature Pipe temperature<br />
thermistor thermistor thermistor thermistor<br />
70 - 3.5 8.8 0.9<br />
80 - 2.5 6.3 -<br />
90 - 1.9 4.7 -<br />
100 - 1.4 3.5 -<br />
During outdoor unit emergency operation or test operation, the LED on the P.C.B. will flash.<br />