4.3 POWER CABLE<br />
7<br />
Figure 4 – Roll Control of the Main Frame<br />
The power cable supplies 12 volt D.C. negative ground power to the<br />
control panel and sensors. The system will function properly with a supply<br />
between 12 and 28 volts and may draw up to 10 amperes during normal<br />
operation.<br />
The UC4 control panel contains intelligent valve drive circuitry that helps<br />
to protect the sprayer’s system against short circuits and other wiring<br />
problems. However, it is still recommended to connect the UC4 power<br />
cable to a fused supply, that turns on and off with the ignition key of the<br />
sprayer/tractor.<br />
4.4 SENSOR CABLES<br />
The UC4 ultrasonic sensors are connected to the control panel via sensor<br />
cables. A generic power cable and a generic extension cable (or a "trunk"<br />
cable) run(s) from the panel to the sprayer boom. From the extension<br />
cable, a standard "branch" cable allows for connection of the two standard<br />
boom sensors and an optional main roll (center) sensor (Figure 5).<br />
Another optional branch cable is required to connect additional sensors.<br />
WING SENSOR<br />
(LO OR RO)<br />
MAIN ROLL<br />
SENSOR (MR)<br />
WING SENSOR<br />
(LO OR RO)<br />
Figure 5 – Sensor Branch Cable<br />
CONNECTS TO<br />
SENSOR TRUNK CABLE