PE57155<br />
Generalities Fault indicators<br />
Easergy Flair is a comprehensive range<br />
of underground network fault current<br />
indicators<br />
Easergy MV underground network fault current passage indicators are a range<br />
of products adapted to all neutral earthing systems: insulated, impedant and<br />
direct earthing.<br />
b Easergy Flair 21D-22D-23DV, are self-powered with a liquid crystal display,<br />
with DIN dimensions for MV cubicle installation.<br />
b Easergy Flair 279 and 219, have a wall-mounted case for the MV cubicles<br />
substation or LV compartment and anexternal power supply which can be backed up.<br />
b Easergy Flair 200C (communicative) has advanced measurement functions and<br />
long distance communication features (radio, GSM, RTC, etc.).<br />
34 AMTED398078EN.indd<br />
PE57154<br />
PE57922<br />
Easergy Flair 21D - 22D - 23DV 279 - 219 200C<br />
Usage Underground MV networks, open loop, insulated,<br />
impedant and direct neutral earthing systems.<br />
Installation Flush fi tted Casing Casing<br />
Power supply Self-powered 230 Vac<br />
230 Vac<br />
or dual power or battery<br />
Fault detection Phase-phase and phase-earth for all 3 ranges<br />
Indication LCD display Indicator light Indicator light (option)<br />
Measurement Current,<br />
frequency<br />
Communication SCADA interface<br />
by dry contact<br />
Easergy Flair 21D - 22D - 23DV<br />
SCADA interface<br />
by dry contact<br />
PE57921<br />
Current, voltage,<br />
power<br />
Long distance (radio,<br />
PSTN, GSM, etc.)<br />
SM6 integrates Flair 21D, Flair 22D and Flair 23DV on every incoming cubicles.<br />
b High performance indicators<br />
v indication of phase-phase and phase-earth faults,<br />
v faulty phase indication,<br />
v compatible with HV/MV substation protection devices.<br />
b Clear and comprehensive display<br />
v displaying the faulty phase for earth fault,<br />
v displaying settings,<br />
v displaying the load current including peak demand and frequency meter.<br />
b Maintenance free.<br />
Flair 21D Flair 22D Flair 23DV<br />
Power supply<br />
Self-powered b b b<br />
Dual power supply<br />
Display of settings<br />
b (battery) b (external)<br />
Short-circuit fault thresholds b b b<br />
Earth fault thresholds b b b<br />
Validation (no current) b b b<br />
Reset upon return of current b b b<br />
Reset timer<br />
Faulty phase and measurements<br />
b b<br />
Faulty phase<br />
L1-L2-L3<br />
L1-L2-L3 L1-L2-L3<br />
Load current b b b<br />
MV network frequency 50/60 Hz 50/60 Hz<br />
Peak demand current b b<br />
Residual current b b