Modular units
Modular units
Modular units
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
DE58360<br />
DE59212-Isc<br />
Characteristics of<br />
the functional <strong>units</strong><br />
DM1-S<br />
Single-isolation<br />
disconnectable CB unit<br />
with independent protection<br />
Electrical characteristics<br />
kA Ik/1s & Isc<br />
25<br />
20<br />
16<br />
12.5<br />
Ir = 630 A<br />
Ir = 400 - 630 A<br />
7.2 12 17.5 24<br />
AMTED398078EN.indd<br />
Ur<br />
kV<br />
DE53536<br />
DE59715<br />
Functional <strong>units</strong> selection<br />
SF6 type circuit breaker protection<br />
DM2<br />
Double-isolation<br />
disconnectable CB unit<br />
Outgoing line on right<br />
kA Ik/1s & Isc<br />
25<br />
20<br />
16<br />
12.5<br />
Basic equipment:<br />
b SF1 disconnectable circuit breaker<br />
b disconnector and earthing switch<br />
b three-phase busbars<br />
b circuit breaker operating mechanism RI<br />
b disconnector operating mechanism CS<br />
b auxiliary contacts on circuit breaker<br />
b mechanical interlocking between circuit breaker and disconnector<br />
b VIP relay<br />
b three CR sensors for VIP relay protection<br />
b voltage presence indicator<br />
b connection pads for dry-type cables<br />
b downstream earthing switch 2 kA rms making capacity<br />
Version:<br />
b Sepam series 10 with auxiliary supply and<br />
three CR sensors<br />
Optional accessories:<br />
b cubicle:<br />
v three voltage transformers<br />
v key-type interlocks<br />
Ir = 630 - 1250 A<br />
Ir = 400 - 630 - 1250 A<br />
Ir =<br />
1250 A<br />
7.2 12 17.5 24 36<br />
b three CTs<br />
b 150 W heating element for 36 kV<br />
v 1250 A three-phase upper busbars at Ir 630 A<br />
v 630 A three-phase upper busbars for severe operating conditions for 24 kV<br />
v enlarged low-voltage control cabinet for 24 kV<br />
v connection enclosure for cabling from above for 24 kV<br />
v 50 W heating element for 24 kV<br />
b circuit breaker:<br />
v motor for operating mechanism<br />
v release <strong>units</strong> (coil)<br />
v operation counter on manual operating mechanism<br />
Ur<br />
kV<br />
DE53537<br />
DE59213<br />
DM2<br />
Double-isolation<br />
disconnectable CB unit<br />
Outgoing line on left<br />
kA Ik/1s & Isc<br />
25<br />
20<br />
16<br />
12.5<br />
Ir = 630 - 1250 A<br />
Ir = 400 - 630 - 1250 A<br />
7.2 12 17.5 24<br />
b cubicle:<br />
v protection using Sepam programmable electronic unit<br />
v auxiliary contacts on disconnectors<br />
v 2 voltage transformers phase-to-phase or 3 voltage transformers phase-to-earth<br />
Ur<br />
kV<br />
51