Generalities Description of the control/<br />

monitoring & protection functions<br />

Sepam selection guide for all applications<br />

The Sepam range of protection and<br />

metering is designed for the operation<br />

of machines and electrical distribution<br />

networks of industrial installations and<br />

utility substations for all levels of voltage.<br />

It consists of complete, simple and reliable<br />

solutions, suited to following four families:<br />

b Sepam series 10,<br />

b Sepam series 20,<br />

b Sepam series 40,<br />

b Sepam series 80.<br />

Series 10 Series 20 Series 40<br />

Protections<br />

Current b b b b b b<br />

Voltage b b b b b<br />

Frequency b b b b b<br />

Specifi cs Phase and<br />

earth fault<br />

overcurrent<br />

A range adapted at your application<br />

b Protection of substation (incoming, outgoing line and busbars).<br />

b Protection of transformers.<br />

b Protection of motors, and generators.<br />

Breaker<br />

failure<br />

Disconnection<br />

by rate of<br />

change of<br />

frequency<br />

Directional<br />

earth fault<br />

Applications<br />

Substation 10A, 10B S20 S24 S40 S41, S43 S42<br />

Busbar B21 B22<br />

Transformer 10A, 10B T20 T24 T40 T42<br />

Motor M20 M41<br />

Generator G40<br />

Capacitor<br />

Characteristics<br />

Logic inputs 4 0 to 10 0 to 10 0 to 10<br />

Logic outputs 7 4 to 8 4 to 8 4 to 8<br />

Temperature sensors 0 to 8 0 to 8 0 to 16<br />

Channel Current 3 I + Io 3 I + Io 3 I + Io<br />

Voltage 3V + Vo 3V, 2U + Vo<br />

LPCT (1) b b<br />

Communication ports 1 1 to 2 1 to 2 1 to 2<br />

IEC61850 Protocol b b b<br />

Control Matrix (2) b b b<br />

Logic equation editor<br />

Logipam<br />

b<br />

(3)<br />

Other Memory cartridge<br />

with settings<br />

Backup battery Lithium battery 48 hours<br />

(1) LPCT: low-power current transformer complying with standard IEC 60044-8.<br />

(2) Control matrix for simple assignment of information from the protection, control and monitoring functions.<br />

(3) Logipam ladder language (PC programming environment) to make full use of Sepam series 80 functions.<br />

Simplicity<br />

Easy to install<br />

b Light, compact base unit.<br />

b Optional modules fi tted on a DIN rail, connected using prefabricated cords.<br />

b User friendly and powerful PC parameter and protection setting software to utilize<br />

all of Sepam’s possibilities.<br />

User-friendly<br />

b Intuitive User Machine Interface, with direct data access.<br />

b Local operating data in the user’s language.<br />

Directional<br />

earth fault<br />

and phase<br />

overcurrent<br />