12.07.2015 Views

PREXTHERM RSW - Ferroli

PREXTHERM RSW - Ferroli

PREXTHERM RSW - Ferroli

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

1. PRESENTATIONDear Customer,Thank you for having chosen a <strong>PREXTHERM</strong><strong>RSW</strong> boiler.This manual has been prepared to provide youwith information, warnings and suggestions onthe installation, correct use and maintenance ofthe boiler. Please therefore read it thoroughlyand keep it with care for future reference.In your interest, we suggest that you carefullyobserve the contents of this manual, so as tobe able to get the most from this high qualityproduct. The Manufacturer declines all liabilityand the warranty will be void in the eventwhere the instructions described in thismanual are not observed.2. GENERAL WARNINGS- This instruction manual is an integral part ofthe product, and provides important instructionsfor installation, operation and maintenance.- This appliance must only be used for the purposesit has been specifically designed for.- This appliance is used to heat water tobelow-boiling temperatures at atmosphericpressure, and must be connected to a centralheating and/or domestic hot waterdistribution system, according to its characteristics,performance and heat output.- Before installation, check that the boiler hasnot been damaged due to handling andtransport.- The boiler must be installed in compliancewith the standards in force, by suitably qualifiedpersonnel.- Before performing any cleaning or maintenanceoperations, disconnect the appliance fromthe mains power supply.- <strong>Ferroli</strong> S.p.A. is not liable for any damage to personspeople and/or things due to errors ininstallation, control, maintenance andimproper use.- The boiler and the corresponding system mustbe commissioned by authorised personnel.- Commissioning is performed in order to checkthe correct operation of all the control devices.- Qualified personnel must be contacted if theappliance is not used for an extended period.StandardsThe installer must observe the local standardsin force as regards: the choice of the site ofinstallation of the boiler, the compliance with therequired ventilation conditions; the tightness ofthe connection to the chimney; the connectionsof the fuel lines, electrical systems and anyother relevant safety standards.Warranty conditionsThe warranty is only valid if the standards andthe suggestions for use described in this manualare observed. Failure to observe such standardsand suggestions will void the warranty.The warranty excludes all damage due to corrosionfrom the acidic condensate of the productsof combustion or the formation of depositscaused by the use of hard or aggressivewater, as such are solely due to the operationof the system.GB3. CERTIFICATIONThe CE Mark attests that <strong>Ferroli</strong> appliancesconform to the requirements specified in theapplicable European directives.In particular, this appliance conforms to the followingEEC directives:- Gas directive (90/396 EEC)- Efficiency directive (92/42 EEC)- Low voltage directive 73/23 EEC(amended by 93/68)- Electromagnetic compatibility directive 89/336(amended by 93/68)4. TECHNICAL AND CONSTRUCTIONALSPECIFICATIONS, DIMENSIONS4.1 Description of the applianceThe construction of the <strong>PREXTHERM</strong> <strong>RSW</strong>series boilers guarantees high output and efficiencyat low flue gas temperatures, thus ensuringreduced polluting emissions.The appliances are made according to the EN303 standard, part 1.The main technical elements of the design are:- the careful design of the shapes, to ensure anoptimum ratio between the combustion volumesand the heat exchange surfaces- the choice of materials used, for the long life ofthe boiler.The boilers feature pressurised combustion,with three flue passes, a horizontal-cylinder configurationand flame reversal in the furnace,completely cooled; the flame produced by theburner is reversed peripherally towards thefront, where the flue gas enters the tube bundle,featuring turbulators to create a swirling paththat increases the heat exchange by convection.On leaving the tube bundle, the flue gas entersthe rear chamber and is transferred to the chimney.The boilers are fitted with a door featuringhinges that can be reversed for opening to theright or the left, and is adjustable in both heightand depth. The body plating is insulated with athick layer of glass wool, and covered with afurther layer of tearproof material. The externalfinish consists of painted steel panels. The hoistinghooks are fitted on the top of the plating.The boilers feature two 1/2” fittings for bulbsheaths (able to house three bulbs each).The pre-wired control panel is located above theboiler, and allows automatic operation.4.2 Operating principleThe <strong>PREXTHERM</strong> <strong>RSW</strong> boilers are fitted with aclosed cylindrical furnace, in which the flame producedby the burner is reversed peripherallytowards the front, from where the burned gasenters the fire tubes. At the outlet, the gas is collectedin the smokebox and is then sent to thechimney. The combustion chamber is alwayspressurised during the operation of the burner.For the pressure values, see the tables on page16, under the column Flue gas side pressure drop.The flue and the flue stack fitting must be madein compliance with the standards and the legislationin force, using rigid pipes that are resistant tohigh temperatures, condensate and mechanicalstress, and are airtight. (Fig. 1)4.3 Technical specifications - Dimensions -Water fittingsKey (Fig. 2 and 3)1 Control panel2 Burner mounting flange3 Smoke box cleaning door4 Flame inspection windowT1 Water deliveryT2 Water returnT3 Expansion vessel connectionT4 Discharge/exhaust boilerT5 Chimney connectionT6 Burner connection4.4 IdentificationThe boiler can be identified from the:- Document envelopeThis is applied to the door, and contains:TECHNICAL MANUALWARRANTY CERTIFICATELABELS WITH BARCODERATING LABELCONSTRUCTION CERTIFICATE(certifying that the water pressure tests havebeen passed)- Rating labelThis describes the technical specificationsand the performance of the appliance (Fig. 4).It is included in the document envelope andMUST BE APPLIED by the installer, wheninstallation is complete, to the top front part ofone of the side panels of the casing, in a visibleposition.If the label is lost, contact the <strong>Ferroli</strong>Technical Service for a duplicate.Tampering with or the removal or absence ofrating labels or other means enabling the unit tobe identified causes problems during installationand maintenance.Key (Fig. 4)1 Document envelope- 15 -

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!