Reported Event Corrective Action<br />
System was shut down<br />
abnormally.<br />
CPU temperature is<br />
higher than 58°C/138°F.<br />
System will shut down.<br />
System fan speed is lower<br />
than 1800 RPM. Check<br />
the system before<br />
continuing.<br />
AC Power failure. System<br />
will shut down.<br />
Disk Drives<br />
Task X timeout on disk Y<br />
at LBA [address]<br />
Task X disk error on disk<br />
Y at LBA [address] with<br />
status Z<br />
S.M.A.R.T threshold<br />
exceeded on disk X<br />
BSL update on disk X at<br />
LBA [address]<br />
The <strong>SmartStor</strong> shut down incorrectly the last time.<br />
See “Shutting Down the <strong>SmartStor</strong>” on page 167.<br />
Allow the <strong>SmartStor</strong> to cool for several minutes. Then<br />
restart the <strong>SmartStor</strong> and check system temperature<br />
and fan operation. See page 169.<br />
Be sure there is adequate air circulation around the<br />
<strong>SmartStor</strong>.<br />
Try enabling or disabling the Smart Fan. See<br />
page 169. If the fan still runs below 1800 RPM,<br />
contact Technical Support. See page 205.<br />
Restore the AC power. Then restart the <strong>SmartStor</strong>.<br />
See “Connecting the Power” on page 8.<br />
A LBA error. Check the disk drives. See page 182.<br />
Check the RAID Volume. See page 184. Replace the<br />
disk drive or rebuild the RAID Volume as needed.<br />
Check the disk drives. See page 182. Replace the<br />
failed drive. See page 183.<br />
Bad sector on a disk drive. Check the disk drives.<br />
See page 182. Replace the disk drive if it continues to<br />
receive BSL updates.<br />
BSL log disk X at LBA Check the disk drives. See page 182.<br />
[address] cleared<br />
Delete Spare Disk Delete a spare drive. Normal.<br />
RAID Volumes<br />
Create [RAID name, Create a RAID Volume. Normal.<br />
RAID level and X number<br />
of disk drives]<br />
Delete RAID X Delete a RAID Volume. Normal.<br />
Migration or Rebuilding<br />
on array X started.<br />
Migration or Rebuilding<br />
on array X at Y%.<br />
RAID Volume Migration or Rebuild has started.<br />
Normal.<br />
Progress report on RAID Volume Migration or<br />
Rebuild. Normal.<br />