23.03.2013 Views

SmartStor NS4600 Product Manual - Promise Technology, Inc.

SmartStor NS4600 Product Manual - Promise Technology, Inc.

SmartStor NS4600 Product Manual - Promise Technology, Inc.

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>SmartStor</strong> <strong>NS4600</strong> <strong>Product</strong> <strong>Manual</strong><br />

Reported Event Corrective Action<br />

System was shut down<br />

abnormally.<br />

CPU temperature is<br />

higher than 58°C/138°F.<br />

System will shut down.<br />

System fan speed is lower<br />

than 1800 RPM. Check<br />

the system before<br />

continuing.<br />

AC Power failure. System<br />

will shut down.<br />

Disk Drives<br />

Task X timeout on disk Y<br />

at LBA [address]<br />

Task X disk error on disk<br />

Y at LBA [address] with<br />

status Z<br />

S.M.A.R.T threshold<br />

exceeded on disk X<br />

BSL update on disk X at<br />

LBA [address]<br />

The <strong>SmartStor</strong> shut down incorrectly the last time.<br />

See “Shutting Down the <strong>SmartStor</strong>” on page 167.<br />

Allow the <strong>SmartStor</strong> to cool for several minutes. Then<br />

restart the <strong>SmartStor</strong> and check system temperature<br />

and fan operation. See page 169.<br />

Be sure there is adequate air circulation around the<br />

<strong>SmartStor</strong>.<br />

Try enabling or disabling the Smart Fan. See<br />

page 169. If the fan still runs below 1800 RPM,<br />

contact Technical Support. See page 205.<br />

Restore the AC power. Then restart the <strong>SmartStor</strong>.<br />

See “Connecting the Power” on page 8.<br />

A LBA error. Check the disk drives. See page 182.<br />

Check the RAID Volume. See page 184. Replace the<br />

disk drive or rebuild the RAID Volume as needed.<br />

Check the disk drives. See page 182. Replace the<br />

failed drive. See page 183.<br />

Bad sector on a disk drive. Check the disk drives.<br />

See page 182. Replace the disk drive if it continues to<br />

receive BSL updates.<br />

BSL log disk X at LBA Check the disk drives. See page 182.<br />

[address] cleared<br />

Delete Spare Disk Delete a spare drive. Normal.<br />

RAID Volumes<br />

Create [RAID name, Create a RAID Volume. Normal.<br />

RAID level and X number<br />

of disk drives]<br />

Delete RAID X Delete a RAID Volume. Normal.<br />

Migration or Rebuilding<br />

on array X started.<br />

Migration or Rebuilding<br />

on array X at Y%.<br />

RAID Volume Migration or Rebuild has started.<br />

Normal.<br />

Progress report on RAID Volume Migration or<br />

Rebuild. Normal.<br />

190

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!