Page 16<br />

➂<br />

MAIN MENU ➀ ➄ 13<br />

METER HARMONICS VIEW SETTINGS PROGRAM SETTINGS<br />

➁ ➁<br />

➁ ➃ ➁ 24 11<br />

Phase A Current<br />

Phase A<br />

Phase B Current<br />

THD Magnitude<br />

➅<br />

Configuration<br />

Phase C Current<br />

Phase B<br />

THD Magnitude<br />

Protection<br />

➅<br />

Ground Current<br />

Neutral Current<br />

Min Max Current<br />

Power<br />

Peak Demand<br />

Total Energy<br />

Forward Energy<br />

Reverse Energy<br />

System Power Factor<br />

4 17<br />

Voltage A-B<br />

Voltage B-C<br />

Voltage C-A<br />

Voltage A-N<br />

Voltage B-N<br />

Voltage C-N<br />

➆ ➉<br />

➅<br />

Min A<br />

Current<br />

Max A<br />

Current<br />

Min B<br />

Current<br />

Max B<br />

Current<br />

Min C<br />

Current<br />

Max C<br />

Current<br />

Min<br />

Ground<br />

Current<br />

Max<br />

Ground<br />

Current<br />

Min<br />

Neutral<br />

Current<br />

Max<br />

Neutral<br />

Current<br />

Reset<br />

Phase C<br />

THD Magnitude<br />

Phase A<br />

(%) Harmonic Content<br />

Phase B<br />

(%) Harmonic Content<br />

Phase C<br />

(%) Harmonic Content<br />

➂<br />

Ground<br />

THD Magnitude<br />

Ground<br />

(%) Harmonic Content<br />

Neutral<br />

(%) Harmonic Content<br />

18<br />

Neutral<br />

THD Magnitude<br />

4<br />

19<br />

➅<br />

➅<br />

➅<br />

➅<br />

➅<br />

Fundamental<br />

thru 27 Harmonics<br />

Fundamental<br />

thru 27 Harmonics<br />

Fundamental<br />

thru 27 Harmonics<br />

Fundamental<br />

thru 27 Harmonics<br />

Fundamental<br />

thru 27 Harmonics<br />

Figure 4-1 <strong>Breaker</strong> <strong>Interface</strong> <strong>Module</strong> Menu Diagram — (continued to next page)<br />

➉<br />

Firmware Versions & Revisions<br />

Number of Poles<br />

Phase A Indicator<br />

Frequency<br />

Sentinel CT Ratio<br />

Sentinel VAR Sign Convention<br />

Sentinel Wiring Scheme<br />

Waveform Acquisition Interval<br />

Sliding Window Assignment<br />

➆/➇ ➉ 20<br />

Pulse Initiation<br />

➂<br />

Device Alarms<br />

BIM Alarm<br />

No Response Enable<br />

Memory Error Enable<br />

Bad Frame Enable<br />

<strong>Breaker</strong> Trip Enable<br />

Long Delay Enable<br />

Ground Overcurrent Enable<br />

Neutral Overcurrent Enable<br />

High Load Enable<br />

Operations Enable<br />

kVA Demand Enable<br />

kW Demand Enable<br />

Demand Peak Exceeded Setting<br />

WH Pulse Initiator Setting<br />

Power Factor Enable<br />

THD Enable<br />

Undervoltage Enable<br />

Overvoltage Enable<br />

Underfrequency Enable<br />

Overfrequency Enable<br />

Reverse Phase Sequence Enable<br />

➆/➇ ➉ 20<br />

➅<br />

➅<br />

➈<br />

➈<br />

Ground Setting<br />

Neutral Setting<br />

High Load Setting<br />

High Load Time<br />

Operations Setting<br />

kVA Demand Setting<br />

kW Demand Setting<br />

Power Factor Setting<br />

THD Setpoints<br />

Log Enable<br />

Undervoltage Setting<br />

Undervoltage Time<br />

Overvoltage Setting<br />

Overvoltage Time<br />

Underfrequency Pickup<br />

Underfrequency Time<br />

Overfrequency Pickup<br />

Overfrequency Time<br />

Reverse Phase Sequence<br />

➆/➇ ➉ 20<br />

I.B. 29C893B<br />

Frame Size<br />

Rating Plug<br />

Long Delay Action<br />

Long Delay Slope<br />

Long Delay Setting<br />

Long Delay Time<br />

Powered Thermal Memory<br />

Unpowered Thermal Memory<br />

Short Delay Action<br />

Short Delay Slope<br />

Short Delay Setting<br />

Short Delay Time<br />

Instantaneous Action<br />

Instantaneous Setting<br />

Discriminator<br />

Ground Fault Action<br />

Ground Fault Slope<br />

Ground Fault Setting<br />

Ground Fault Time<br />

Ground Current Sense<br />

Ground Scale Factor<br />

<strong>Breaker</strong> Neutral Ratio<br />

Amp Out Of Balance Trip<br />

Amp Out Of Balance Time<br />

Phase Loss Trip Time<br />

Undervoltage Trip Setting<br />

Undervoltage Trip Time<br />

Underfrequency Trip Pickup<br />

Underfrequency Trip Time<br />

Overfrequency Trip Pickup<br />

Overfrequency Trip Time<br />

Reverse Power Trip Action<br />

Reverse Power Trip Time<br />

➆/➇ ➉ 20<br />

Effective 2/01<br />

28<br />

28<br />

28<br />

28<br />

21