Breaker Interface Module II - Eaton Canada
Breaker Interface Module II - Eaton Canada
Breaker Interface Module II - Eaton Canada
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Page 34<br />
➄ Terminating<br />
Resistor<br />
➀<br />
Shielded<br />
Twisted<br />
Pair<br />
DS<strong>II</strong><br />
Circuit<br />
<strong>Breaker</strong><br />
with<br />
OPTIM<br />
➆<br />
PONI <strong>Module</strong><br />
(Required for IMPACC<br />
Network Communications)<br />
Series C<br />
K-Frame<br />
MCCB<br />
with<br />
OPTIM<br />
Shielded<br />
Twisted<br />
Pair<br />
➁<br />
➃<br />
➁<br />
Series C<br />
L-Frame<br />
MCCB<br />
with<br />
OPTIM<br />
IBM Compatible<br />
Computer<br />
PONI<br />
<strong>Breaker</strong><br />
<strong>Interface</strong><br />
<strong>Module</strong><br />
➀ ➂<br />
SPB<br />
Circuit<br />
<strong>Breaker</strong><br />
with<br />
OPTIM<br />
Circuit<br />
<strong>Breaker</strong><br />
with<br />
RMS 810<br />
or 910<br />
➄ Terminating<br />
Resistor<br />
Figure 5-3 Typical Network Wiring Diagram<br />
➅<br />
➁<br />
➃<br />
Series C<br />
N-Frame<br />
MCCB<br />
with<br />
OPTIM<br />
Series C<br />
R-Frame<br />
MCCB<br />
with<br />
OPTIM<br />
➁ ➁<br />
Series C<br />
F-Frame<br />
MCCB<br />
ES<br />
Shielded<br />
Twisted<br />
Pair<br />
IQ Energy Sentinel<br />
➀<br />
I.B. 29C893B<br />
➀ For network interconnection cable,<br />
use Belden 9463 or Cutler-Hammer<br />
IMPCABLE.<br />
➁ When interconnecting devices, tie<br />
shield drain wires together for shield<br />
path continuity.<br />
➂ Connect the shield path to a solid<br />
earth ground at one point only.<br />
➃ On last device in network, tape shield<br />
drain wire back upon cable.<br />
➄ Use a 1/2 watt carbon or metal film<br />
resistor at each end of the network<br />
as an end of line termination resistor<br />
(EOLTR). EOLTR should be 100 ohms<br />
for 9600 baud communication rate<br />
networks or 150 ohms for 1200 baud<br />
communication rate networks.<br />
➅ Network interconnection to computer<br />
requires use of an IMPACC master<br />
(CONI or MINT).<br />
➆ Devices without built-in communications<br />
require network interface module<br />
(PONI).<br />
For detailed network wiring specifications,<br />
call the automatic fax retrieval system<br />
(FRED) at 412/494-3745 and request<br />
document 17513 or contact the<br />
Advanced Products Support Center.<br />
Refer to the paragraph entitled<br />
“Technical Assistance” in this document.<br />
Effective 2/01