04.05.2013 Views

Final EIAR - Aurecon AME Environmental | Environmental Projects

Final EIAR - Aurecon AME Environmental | Environmental Projects

Final EIAR - Aurecon AME Environmental | Environmental Projects

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Proposed Wind and Solar (Photovoltaic) Energy Facilities on Kangnas Farm near Springbok in the Northern Cape: <strong>Final</strong> EIR 110<br />

The same measures as recommended for the proposed wind energy facility should be<br />

implemented.<br />

4.4.4 Sedimentation and erosion of watercourses<br />

The site is situated on a watershed between the Orange River and the Buffels River with the<br />

main freshwater features being a number of small ephemeral streams that drain the inselbergs<br />

for a short period following rainfall events, two small springs/well points and some ephemeral<br />

pans at Kangnas and Koeris farms. The ephemeral tributaries of the Buffels and Orange rivers<br />

within the site are considered to be in a largely natural to moderately modified ecological state.<br />

The sediment loads of any drainage depressions or pans may increase due to the excavations<br />

on the site, the laying of linear infrastructure such as roads or power lines across drainage lines<br />

and other construction related activities.<br />

The potential impact of sedimentation and erosion from the construction of the proposed wind<br />

energy facility is considered to be of medium to high magnitude, site specific and short term<br />

and therefore of low (-) significance, without mitigation. The potential of this impact would<br />

reduce to very low (-) significance, after mitigation.<br />

The potential impact of disturbance of freshwater related habitats in the actual solar<br />

development zone is considered to be of moderate magnitude, site specific and short term and<br />

therefore of very low (-) significance, with and without mitigation.<br />

The following mitigation measures are recommended for the wind energy facility:<br />

• Wind turbines should be located outside of any of the identified drainage channels, as is<br />

currently the case.<br />

• Construction activities should as far as possible be limited to the identified sites for the<br />

proposed wind energy facility and the identified access routes.<br />

• Where transmission lines need to be constructed over/through the drainage channels,<br />

disturbance of the channels should be limited. These areas should be rehabilitated after<br />

construction is complete.<br />

• Existing road infrastructure should be utilized as far as possible to minimize the overall<br />

disturbance created by the proposed projects. Where access routes need to be<br />

constructed through ephemeral streams, disturbance of the channel should be limited.<br />

• All crossings over drainage channels or stream beds should be such that the flow within<br />

the drainage channel is not impeded.<br />

• Road infrastructure and power transmission lines should coincide as much as possible<br />

to minimize the impact.<br />

• Any disturbed areas should be rehabilitated to ensure that these areas do not become<br />

subject to erosion or invasive alien plant growth.<br />

• All crossings over drainage channels or stream beds after the construction phase should<br />

be rehabilitated such that the flow within the drainage channel is not impeded.<br />

• A buffer of 30 m (measured from top of bank) should be maintained adjacent to the<br />

identified ephemeral streams and 500m from the springs.<br />

• All materials on the construction sites should be properly stored and contained. Disposal<br />

of waste from the sites should also be properly managed. Construction workers should<br />

be given ablution facilities at the construction sites that are located at least 100 m away<br />

from any drainage areas/ephemeral streams and regularly serviced. These measures<br />

© <strong>Aurecon</strong> (2012) No unauthorised reproduction, copy<br />

or adaptation, in whole or in part, may be made.<br />

P:\<strong>Projects</strong>\108495 Kangnas WEF & PV EIA's\3 Project Delivery\4 Reports\FEIR\FEIR 210213 <strong>Final</strong>.doc

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!