water tables (see Chapter 3). Corrective actions include improving<br />

surface drainage by regrading or filling low areas. High water table<br />

conditions may be corrected in some instances by installing drains (see<br />

Section 7.2.6).<br />

Lack of maintenance of the treatment unit preceding<br />

field may also be a cause of occasional failure.<br />

point of infiltration <strong>and</strong> inflow during wet periods.<br />

pumped <strong>and</strong> leaks repaired.<br />

the soil absorption<br />

The unit may be a<br />

The unit should be<br />

Continuous Failure: The causes of.continuous failure are more difficult<br />

to determine. However, learning the age of the system when failure<br />

first occurred is very useful in isolating the cause.<br />

If failure occurred within the first year of operation, the cause is<br />

probably due to poor siting, design, or construction. It is useful to<br />

check the performance of neighboring systems installed in similar<br />

soils. If they have similar loading rates <strong>and</strong> are working well, the<br />

failing system should be checked for proper sizing. A small system can<br />

be enlarged by adding new infiltration areas. In some instances, the<br />

sizing may be adequate but the distribution of the wastewater is poor<br />

due to improper construction. Providing dosing may correct this problem<br />

(see Section 7.2.8). Damage to the soil during construction may also<br />

cause failure, in which case the infiltrative area is less effective.<br />

Reconstruction or an addition is necessary. Alternate systems should be<br />

considered if the site is poor. This includes investigating the fea-<br />

sibility of a cluster or community system if surrounding systems are<br />

experiencing similar problems.<br />

If the system had many years of useful service before failure occurred,<br />

hydraulic overloading or poor maintenance is usually the cause. The<br />

first step is to find out as much about the system as possible. A<br />

sketch of the system showing the size, configuration, <strong>and</strong> location<br />

should be made. A soil profile description should also be obtained.<br />

These items may be on file at the local regulatory agency but their ac-<br />

curacy should be confirmed by an onsite visit. If the system provided<br />

several years of useful service, evidences of overloading should be<br />

investigated first. <strong>Wastewater</strong> volume <strong>and</strong> characteristics (solids,<br />

greases, fats, oil) should be determined. Overloading may be corrected<br />

by repairing plumbing, installing flow reduction fixtures (see Chapter<br />

51, <strong>and</strong> eliminating any discharges from foundation drains. If the vol-<br />

ume reductions are insufficient for acceptance by the existing infiltra-<br />

tive surface, then additional infiltrative areas must be constructed.<br />

<strong>Systems</strong> serving commercial buildings may fail because of the'wastewater<br />

characteristics. High solids concentrations or large amounts of fats,<br />