Power distribution components<br />

3+3 Base Raceway<br />

six circuit, ten-wire raceway for panels<br />

jumpers and infeed<br />

AutoStrada<br />

description type w d h pattern no. list price<br />

Jumper 18 panel 38 2 2 RR3-TJ18 $121.<br />

20 panel 40 2 2 RR3-TJ20 121.<br />

24 panel 44 2 2 RR3-TJ24 132.<br />

30 panel 50 2 2 RR3-TJ30 138.<br />

36 panel 56 2 2 RR3-TJ36 145.<br />

42 panel 62 2 2 RR3-TJ42 160.<br />

48 panel 68 2 2 RR3-TJ48 175.<br />

54 panel run 76 1 /2 2 2 RR3-TJ54P 183.<br />

60 panel 82 1 /2 2 2 RR3-TJ60P 191.<br />

66 panel run 86 1 /2 2 2 RR3-TJ66P 200.<br />

72 panel run 94 1 /2 2 2 RR3-TJ72P 207.<br />

78 panel run 100 1 /2 2 2 RR3-TJ78P 212.<br />

84 panel run 106 1 /2 2 2 RR3-TJ84P 232.<br />

90 panel run 112 1 /2 2 2 RR3-TJ90P 237.<br />

96 panel run 118 1 /2 2 2 RR3-TJ96P 243.<br />

Extended jumper 18 + post 40 1 /2 2 2 RR3-TJ18P 121.<br />

20 + post 46 1 /2 2 2 RR3-TJ20P 121.<br />

24 + post 46 1 /2 2 2 RR3-TJ24P 132.<br />

30 + post 52 1 /2 2 2 RR3-TJ30P 138.<br />

36 + post 58 1 /2 2 2 RR3-TJ36P 145.<br />

42 + post 64 1 /2 2 2 RR3-TJ42P 160.<br />

48 + post 70 1 /2 2 2 RR3-TJ48P 175.<br />

Power infeeds Ceiling power cable infeed. Ten-wire RR3-TPVR 351.<br />

Hardwire infeed (NYC) one direction ** RR3-TPNY1 243.<br />

Hardwire infeed (NYC) two directions ** RR3-TPNY2 351.<br />

Panel base end feed RR3-RTPI 290.<br />

Panel base side infeed RR3-TPI 290.<br />

Surge suppressors * RR3-SP-(A, B, C, X, Y, Z) 183.<br />

* Select which circuit needs protecting and order the specified surge processor.<br />

** For RR3-TPNY1 and RR3-TPNY2 specify base height of panel for NYC.<br />

Order Code<br />

Example: RR3-TPVR<br />

RR3 Reff raceway<br />

T Ten wire 3+3<br />

P power infeed<br />

VR for vertical raceway<br />

Specification Information<br />

Reff 3+3 Raceway is a six-circuit,<br />

ten-wire modular power distribution<br />

system for use in Reff panels. 3+3<br />

Raceway components distribute<br />

three 20-amp convenience circuits<br />

(A, B and C) with neutral and<br />

ground, and three 20-amp circuits<br />

(X, Y and Z) with separate neutral<br />

and ground.<br />

In Canada, circuits carry a 15 amp<br />

load rating.<br />

Power infeeds connect building<br />

power supply to a cluster of<br />

interconnected power rails. Panel<br />

base infeed snaps into any outlet<br />

position in rail, and includes 6 foot<br />

liquid-tight conduit and pigtail for<br />

connection to floor or wall electrical<br />

box. Ceiling infeeds include up to<br />

13 pigtail for connection into panel<br />

base through standard power pole.<br />

Power pole and post must be<br />

ordered separately.<br />

134<br />

Hardwire infeed, used in all New<br />

York City installations, includes<br />

junction box that mounts within<br />

non-powered panel base (any width<br />

30 or greater). Electrical contractor<br />

supplies watertight conduit from<br />

building power supply to panel and<br />

trims power connectors to length.<br />

RR3-TPNY2 includes two power<br />

connectors to power panels on both<br />

sides of infeed panel; RR3-TPNY1<br />

includes only one power connector.<br />

Note:<br />

For NYC hardwire infeeds specify<br />

bracket height: 4,5,or6H.<br />

Application Notes<br />

Jumpers pass power through the<br />

raceway of panels that do not<br />

require power access to the next<br />

available power rail. Jumpers only<br />

connect to power rails. Jumpers 18<br />

to 48 are available standard or<br />

extended. Extended jumpers should<br />

be specified when passing through a<br />

panel and a post. Jumpers 54 to 96<br />

wide can be used with or without a<br />

post application. Extended jumpers<br />

and jumpers 54 to 96 wide can<br />

only pass through panels and one<br />

post.<br />

Cable sizes are nominal. Use the<br />

‘‘type’’ column to specify the<br />

required cable for your panel.<br />

Beltway panels can use jumpers at<br />

the panel base in a straight run or<br />

around a corner.