In the event of an overtemperature condition, prtdiag reports an error in the Status<br />

column.<br />

CODE EXAMPLE 8-9<br />

prtdiag Overtemperature Indication Output<br />

System Temperatures (Celsius):<br />

-------------------------------<br />

Device Temperature Status<br />

---------------------------------------<br />

CPU0 62 OK<br />

CPU1 102 ERROR<br />

Similarly, if there is a failure of a particular component, prtdiag reports a fault in<br />

the appropriate Status column.<br />

CODE EXAMPLE 8-10<br />

prtdiag Fault Indication Output<br />

Fan Status:<br />

-----------<br />

Bank RPM Status<br />

---- ----- ------<br />

CPU0 4166 [NO_FAULT]<br />

CPU1 0000 [FAULT]<br />

Using the prtfru Command<br />

The <strong>Sun</strong> <strong>Fire</strong> <strong>V445</strong> system maintains a hierarchical list of all FRUs in the system, as<br />

well as specific information about various FRUs.<br />

184 <strong>Sun</strong> <strong>Fire</strong> <strong>V445</strong> <strong>Server</strong> <strong>Administration</strong> <strong>Guide</strong> • August 2006