The prtfru command can display this hierarchical list, as well as data contained in<br />
the serial electrically-erasable programmable read-only memory (SEEPROM) devices<br />
located on many FRUs. CODE EXAMPLE 8-11 shows an excerpt of a hierarchical list of<br />
FRUs generated by the prtfru command with the -l option.<br />
CODE EXAMPLE 8-11<br />
prtfru -l Command Output (Truncated)<br />
# prtfru -l<br />
/frutree<br />
/frutree/chassis (fru)<br />
/frutree/chassis/MB?Label=MB<br />
/frutree/chassis/MB?Label=MB/system-board (container)<br />
/frutree/chassis/MB?Label=MB/system-board/FT0?Label=FT0<br />
/frutree/chassis/MB?Label=MB/system-board/FT0?Label=FT0/fan-tray (fru)<br />
/frutree/chassis/MB?Label=MB/system-board/FT0?Label=FT0/fan-tray/F0?Label=F0<br />
/frutree/chassis/MB?Label=MB/system-board/FT1?Label=FT1<br />
/frutree/chassis/MB?Label=MB/system-board/FT1?Label=FT1/fan-tray (fru)<br />
/frutree/chassis/MB?Label=MB/system-board/FT1?Label=FT1/fan-tray/F0?Label=F0<br />
/frutree/chassis/MB?Label=MB/system-board/FT2?Label=FT2<br />
/frutree/chassis/MB?Label=MB/system-board/FT2?Label=FT2/fan-tray (fru)<br />
/frutree/chassis/MB?Label=MB/system-board/FT2?Label=FT2/fan-tray/F0?Label=F0<br />
/frutree/chassis/MB?Label=MB/system-board/FT3?Label=FT3<br />
/frutree/chassis/MB?Label=MB/system-board/FT4?Label=FT4<br />
/frutree/chassis/MB?Label=MB/system-board/FT5?Label=FT5<br />
/frutree/chassis/MB?Label=MB/system-board/FT5?Label=FT5/fan-tray (fru)<br />
/frutree/chassis/MB?Label=MB/system-board/FT5?Label=FT5/fan-tray/F0?Label=F0<br />
/frutree/chassis/MB?Label=MB/system-board/C0?Label=C0<br />
/frutree/chassis/MB?Label=MB/system-board/C0?Label=C0/cpu-module (container)<br />
/frutree/chassis/MB?Label=MB/system-board/C0?Label=C0/cpu-module/P0?Label=P0<br />
/frutree/chassis/MB?Label=MB/system-board/C0?Label=C0/cpu-module/P0?Label=<br />
P0/cpu<br />
/frutree/chassis/MB?Label=MB/system-board/C0?Label=C0/cpu-module/P0?Label=<br />
P0/cpu/B0?Label=B0<br />
CODE EXAMPLE 8-12 shows an excerpt of SEEPROM data generated by the prtfru<br />
command with the -c option.<br />
CODE EXAMPLE 8-12<br />
prtfru -c Command Output<br />
# prtfru -c<br />
/frutree/chassis/MB?Label=MB/system-board (container)<br />
SEGMENT: FD<br />
/Customer_DataR<br />
/Customer_DataR/UNIX_Timestamp32: Wed Dec 31 19:00:00 EST 1969<br />
/Customer_DataR/Cust_Data:<br />
/InstallationR (4 iterations)<br />
/InstallationR[0]<br />
/InstallationR[0]/UNIX_Timestamp32: Fri Dec 31 20:47:13 EST 1999<br />
Chapter 8 Diagnostics 185