GENERAL<br />

2 BOILER DIMENSIONS, SERVICES & CLEARANCES all dimensions in mm<br />

The boiler connections are made on the boiler. Refer to<br />

Frames 30.<br />

The following minimum clearances must be maintained for<br />

operation and servicing.<br />

Additional space will be required for installation, depending<br />

upon site conditions.<br />

Side and Rear Flue<br />

Provided that the flue hole is cut accurately, e.g. with a core drill,<br />

the flue can be installed from inside the building where wall<br />

thicknesses do not exceed 600mm. Where the space into which<br />

the boiler is going to be installed is less than the length of flue<br />

required the flue must be fitted from the outside.<br />

Front clearance - The minimum front clearance when built in to a cupboard is 5mm from the cupboard door but 450mm<br />

overall clearance is still required, with the cupboard door open, to allow for servicing.<br />

* Bottom clearance - Bottom clearance after installation can be reduced to 5mm. However, 200mm must be available for<br />

servicing.<br />

53<br />

49<br />

Condensate<br />

Drain<br />

CH Flow<br />

CLEARANCES<br />

5<br />

5<br />

460<br />

DHW Out<br />

Gas<br />

DHW In<br />

160<br />

200*<br />

WATER AND GAS CONNECTIONS<br />

CH Return<br />

129 65 46 70 65 31<br />

750<br />

PRV<br />

44<br />

esp8820<br />

BOILER DIMENSIONS<br />

SIDE FLUE ONLY<br />

Horizontal length of flue Top clearance<br />

from centre line of boiler required (MIN.)<br />

to outside wall Dim. A<br />

HE24 HE30 HE35<br />

0.5 m 0.5 m 0.5 m 160 mm<br />

1.0 m 1.0 m 1.0 m 170 mm<br />

1.5 m 1.5 m 1.5 m 185 mm<br />

2.0 m 2.0 m 2.0 m 200 mm<br />

2.5 m 2.5 m 2.5 m 210 mm<br />

3.0 m 3.0 m 3.0 m 225 mm<br />

3.5 m 3.5 m N/A 250 mm<br />

4.0 m 4.0 m N/A 260 mm<br />

4.5 m 4.5 m N/A 265 mm<br />

5.0 m 5.0 m N/A 275 mm<br />

5.5 m 5.5 m N/A 290 mm<br />

6.0 m 6.0 m N/A 300 mm<br />

REAR FLUE ONLY<br />

MIN. Top clearance required = 160 mm<br />

10 Esprit - Installation and Servicing<br />

450<br />

330<br />

64mm<br />

Wall<br />

Mounting<br />

Plate