SERVICING<br />
48<br />
SERVICING<br />
64 CONDENSATE TRAP/SIPHON REPLACEMENT<br />
1. Refer to Frame 52.<br />
2. Swing the control box down into the servicing position.<br />
Refer to Frame 46.<br />
3. Pull off the rubber top pipe.<br />
4. Undo the siphon plastic union connection.<br />
65 DHW THERMISTOR REPLACEMENT<br />
1. Refer to Frames 52 & 72 for draining the appliance.<br />
2. Swing the control box into the servicing position. Refer<br />
to Frame 46.<br />
3. Drain the DHW circuit. Refer to Frame 72.<br />
4. Unscrew the knurled retaining nut.<br />
5<br />
4<br />
5. Remove the backnut retaining the siphon to the bottom<br />
panel.<br />
6. Fit the new siphon in reverse order ensuring the siphon<br />
is full of water.<br />
7. Check operation of the boiler. Refer to Frame 52.<br />
3<br />
5. Disconnect the in line electrical connection and<br />
withdraw the thermistor.<br />
6. Reassemble in reverse order.<br />
7. Check operation of the boiler. Refer to Frame 52.<br />
4<br />
5<br />
Esprit - Installation and Servicing