Esprit - Installation and Servicing<br />
INSTALLATION<br />
34 CONT’D ..........ELECTRICAL CONNECTIONS - INSTALLER WIRING<br />
<strong>Ideal</strong> Boilers offer 4 kits as follows:<br />
(see individual kits for installation instructions)<br />
PROGRAMMER KIT MECHANICAL 24 HOUR- 24 hour mechanical programmer fits into the control box of the boiler. This can be<br />
fitted in conjunction with a room thermostat.<br />
PROGRAMMER KIT ELECTRONIC 7 DAY - 7 day electronic programmer fits into the control box of the boiler. This can be fitted in<br />
conjunction with a room thermostat.<br />
RF THERMOSTAT/PROGRAMMER KIT MECHANICAL 24 HOUR - Combined 24 hour mechanical programmer and room<br />
thermostat with wireless communication to receiver unit which fits into control box of the boiler.<br />
RF THERMOSTAT/PROGRAMMER KIT ELECTRONIC 7 DAY - Combined 7 day programmer and room thermostat with wireless<br />
communication to receiver unit which fits into control box of the boiler.<br />
ROOM THERMOSTAT (NO PROGRAMMER)<br />
1. Remove link wire between R1 and R2.<br />
2. Connect room thermostat across terminals R1 and<br />
R2 as shown in diagram A<br />
3. If room thermostat has a neutral connection,<br />
DIAGRAM A - NO PROGRAMMER<br />
connect this to terminal N (load) in the fused spur.<br />
L<br />
ROOM THERMOSTAT + PROGRAMMER<br />
N<br />
1. Remove link wire between R1 & R2.<br />
F1<br />
2. Connect room thermostat and programmer in<br />
series as shown in diagram B.<br />
F2<br />
3. If room thermostat has a neutral connection,<br />
R1<br />
connect this to terminal N (load) in the fused spur.<br />
R2<br />
R3<br />
FROST THERMOSTAT<br />
If parts of the system are vulnerable to freezing or the<br />
programmer is likely to be left off during cold weather, a<br />
frost thermostat should be fitted.<br />
1. Position the frost thermostat in a suitable position,<br />
i.e. area vulnerable to freezing.<br />
R3 connection is used with<br />
integral programmer kit<br />
2. Connect frost thermostat across terminals<br />
F1 and F2 as shown in diagrams A and B. DIAGRAM B - EXTERNAL PROGRAMMER<br />
L<br />
N<br />
F1<br />
F2<br />
R1<br />
R2<br />
R3<br />
Optional<br />
Frost Stat<br />
External<br />
Programmer<br />
Optional<br />
Frost Stat<br />
N<br />
Room<br />
Stat<br />
esp9396<br />
N<br />
Room<br />
Stat<br />
esp9397<br />
31<br />
INSTALLATION