Esprit - Installation and Servicing<br />

INSTALLATION<br />

34 CONT’D ..........ELECTRICAL CONNECTIONS - INSTALLER WIRING<br />

<strong>Ideal</strong> Boilers offer 4 kits as follows:<br />

(see individual kits for installation instructions)<br />

PROGRAMMER KIT MECHANICAL 24 HOUR- 24 hour mechanical programmer fits into the control box of the boiler. This can be<br />

fitted in conjunction with a room thermostat.<br />

PROGRAMMER KIT ELECTRONIC 7 DAY - 7 day electronic programmer fits into the control box of the boiler. This can be fitted in<br />

conjunction with a room thermostat.<br />

RF THERMOSTAT/PROGRAMMER KIT MECHANICAL 24 HOUR - Combined 24 hour mechanical programmer and room<br />

thermostat with wireless communication to receiver unit which fits into control box of the boiler.<br />

RF THERMOSTAT/PROGRAMMER KIT ELECTRONIC 7 DAY - Combined 7 day programmer and room thermostat with wireless<br />

communication to receiver unit which fits into control box of the boiler.<br />

ROOM THERMOSTAT (NO PROGRAMMER)<br />

1. Remove link wire between R1 and R2.<br />

2. Connect room thermostat across terminals R1 and<br />

R2 as shown in diagram A<br />

3. If room thermostat has a neutral connection,<br />

DIAGRAM A - NO PROGRAMMER<br />

connect this to terminal N (load) in the fused spur.<br />

L<br />

ROOM THERMOSTAT + PROGRAMMER<br />

N<br />

1. Remove link wire between R1 & R2.<br />

F1<br />

2. Connect room thermostat and programmer in<br />

series as shown in diagram B.<br />

F2<br />

3. If room thermostat has a neutral connection,<br />

R1<br />

connect this to terminal N (load) in the fused spur.<br />

R2<br />

R3<br />

FROST THERMOSTAT<br />

If parts of the system are vulnerable to freezing or the<br />

programmer is likely to be left off during cold weather, a<br />

frost thermostat should be fitted.<br />

1. Position the frost thermostat in a suitable position,<br />

i.e. area vulnerable to freezing.<br />

R3 connection is used with<br />

integral programmer kit<br />

2. Connect frost thermostat across terminals<br />

F1 and F2 as shown in diagrams A and B. DIAGRAM B - EXTERNAL PROGRAMMER<br />

L<br />

N<br />

F1<br />

F2<br />

R1<br />

R2<br />

R3<br />

Optional<br />

Frost Stat<br />

External<br />

Programmer<br />

Optional<br />

Frost Stat<br />

N<br />

Room<br />

Stat<br />

esp9396<br />

N<br />

Room<br />

Stat<br />

esp9397<br />

31<br />

INSTALLATION