13 PREPARING THE WALL<br />

IMPORTANT.<br />

Ensure that, during the cutting operation, masonry<br />

falling outside of the building does not cause damage<br />

or personal injury.<br />

1. Cut the flue hole (preferably with a 5" core boring<br />

tool), ensuring that the hole is square to the wall.<br />

Both wall faces immediately around the cut hole<br />

should be flat.<br />

2. Drill 3 holes with an 8mm masonry drill and<br />

insert the plastic plugs, provided, for the wall<br />

mounting plate.<br />

Esprit - Installation and Servicing<br />

INSTALLATION<br />

14 SETTING THE FLUE - REAR Wall thicknesses of 200 to 426mm<br />

Notes.<br />

a. If using the extension ducts go to Frame 16.<br />

b. If the stand-off frame is used it is essential add 33mm to<br />

'X' the measured wall thickness when marking the flue<br />

(this will allow for the fitted frame).<br />

c. For wall thickness less than 200mm use none telescopic<br />

b pack.<br />

1. Measure and note wall thickness X. Refer to Frame 10.<br />

2. Add 85mm (4") to dimension X and set telescopic flue<br />

length as indicated in drawing.<br />

3. Using a 3.5mm drill bit, drill two holes in outer air duct<br />

taking care not to pierce plastic inner flue.<br />

4. Fix to length using self tappers provided.<br />

5. Seal out air duct using the tape provided.<br />

15 SETTING THE FLUE - SIDE Wall thicknesses of 140 to 365mm<br />

Note.<br />

a. If using the extension ducts go to Frame 16.<br />

b. For shorter flue requirements use non telescopic<br />

b pack.<br />

1. Measure and note wall thickness X. Refer to Frame 10.<br />

2. Measure distance from side of boiler to inside of wall<br />

and add to wall thickness X = L. Refer to Frame 10.<br />

3. Add 156mm to dimension L, hand set telescopic flue<br />

length as indicated in drawing.<br />

4. Using a 3.5mm drill bit, drill two holes in outer air duct<br />

taking care not to pierce plastic inner flue.<br />

5. Fix to length using self tappers provided.<br />

6. Seal outer air duct using the tape provided.<br />

esp8938<br />

esp8939<br />

X<br />

Section<br />

through wall<br />

Drill hole<br />

Drill hole<br />

X + 85<br />

Measurement to be<br />

taken from this point<br />

L + 145<br />

Rear flue only<br />

5" diameter hole<br />

Note. Check all of the hole<br />

positions before drilling.<br />

Measurement to be<br />

taken from this point<br />

Adhere sealing tape<br />

Adhere sealing tape<br />

Side flue only<br />

5" diameter hole<br />

esp8816<br />

19<br />

FLUE OUTLET