SERVICING<br />

76 FLOW LIMITER REPLACEMENT<br />

54<br />

1. Refer to frame 52.<br />

2. Isolate the mains cold water supply to the boiler.<br />

3. Drain the boiler DHW circuit. Refer to Frame 72.<br />

4. Unscrew the three union connections at the DHW<br />

isolating valve and remove the valve.<br />

5. Remove the circlip retaining the flow limiter.<br />

6. Using a suitable tool, pull the flow limiter from the<br />

valve body.<br />

7. Fit the new flow limiter and reassemble in<br />

reverse order.<br />

8. Refill the boiler. Refer to Frame 32.<br />

9. Check operation of the boiler. Refer to Frame 52.<br />

4<br />

SERVICING<br />

77 WATER PRESSURE SWITCH REPLACEMENT<br />

1. Refer to frame 52.<br />

2. Swing the control box down into the servicing<br />

position. Refer to Frame 46.<br />

3. Drain the boiler CH circuit. Refer to Frame 72.<br />

4. Pull off the two electrical connections from the<br />

switch.<br />

5. Pull off the earth connection.<br />

6. Unscrew the water pressure switch.<br />

7. Re-assemble in reverse order.<br />

8. Refill the boiler. Refer to Frame 32.<br />

9. Check operation of the boiler. Refer to Frame 52.<br />