74 DHW FLOW SWITCH REPLACEMENT<br />

1. Refer to frame 52.<br />

2. Swing the control box down into the servicing<br />

position. Refer to Frame 46.<br />

3. Unplug the electrical connection.<br />

4. Carefully pull the switch upwards to<br />

disengage.<br />

5. Fit the new switch and replace the electrical<br />

plug connection.<br />

6. Re-assemble in reverse order<br />

7. Check operation of the boiler. Refer to<br />

Frame 52.<br />

75 DHW FILTER REPLACEMENT<br />

1. Refer to frame 52.<br />

2. Swing the control box down into the<br />

servicing position. Refer to Frame 46.<br />

3. Drain the boiler. Refer to Frame 72.<br />

4. Remove the DHW flow switch. Refer to<br />

Frame 74.<br />

5. Unscrew the DHW filter housing from the<br />

main brass body.<br />

6. Remove and fit new filter.<br />

7. Re-assemble in reverse order.<br />

8. Refill the boiler. Refer to Frame 32.<br />

9. Check operation of the boiler. Refer to<br />

Frame 52.<br />